Publicité

Liens rapides

This product is covered by one or more of the following patents.
European Patent 851,211 B1; 1,111,690 B1; 1,148,346 B1; 1,209,487 B1.
Italian Patent IT 1,321,772.
S5N-Mx SERIES
INSTRUCTION MANUAL
Information on IO-Link communication is available on the last
page of this manual.
CONTROLS
OUTPUT LED (S5N-Mx...B01/C01)
The yellow LED ON indicates that the N.O. (normally open) output
status is closed.
STABILITY LED (S5N-Mx...B01/C01)
The green LED ON indicates that the received signal has a reserve
greater than 30% compared to the output switching value.
TRIMMER (S5N-Mx...B01/C01)
The trimmer can be used to adjust sensitivity; the operating distance
increases turning the trimmer clockwise.
WARNING: The trimmer rotation is limited to 270° by a mechanical stop.
Do not apply excessive torque when adjusting (max 40 Nmm).
INSTALLATION
The sensor can be fixed by means of the M18x1 threaded body through
a  18 mm hole, using the two CH.24 nuts enclosed (22 Nm maximum
tightening torque).
Wide range of accessories available: various orientable fixing brackets
ease the sensor positioning (please refer to the accessories listed in the
general catalogue).
The operating distance is measured from the front surface of the sensor
lens.
C models: To improve the detection, the
object has to be moved closer or further away
from the front surface of the sensor lens.
In case of lateral translation, the object must
move as indicated in the figure.
CONNECTIONS
The connections are compliant to the EN 60947-5-2 standard.
M12 CONNECTOR
+
10 ... 30 Vdc
N.C. OUTPUT
2
1
3
4
N.O. OUTPUT/
-
0 V
IO-Link
AXIAL VERSION
L
14.5
4
4
X
2.5
10
TRIMMER
M O D E L S
with trimmer
L
67
X
43
STABILITY LED
49
OUTPUT LED
FIBRE OPTIC VERSION
72.5
12
4
50
TRIMMER
54.5
TECHNICAL DATA
S5N-MA AXIAL VERSION
Power supply:
Ripple:
Current consumption
(output current excluded):
Outputs:
Output current:
Output saturation voltage:
Response time:
Switching frequency:
Indicators:
Setting:
Operating temperature:
Storage temperature:
Dielectric strength:
Insulation resistance:
B01: 0.1...3.5 m on R2
Operating distance (typical values):
C01: 0...60 cm
Emission type:
Ambient light rejection:
0.5 mm amplitude, 10 ... 55 Hz frequency, for every axis (EN60068-2-6)
Vibrations:
Shock resistance:
Housing material:
Lens material:
Mechanical protection:
Connections:
Weight:
AtEx 2014/34/EU
I I 3G EX nA II T6 ;
I I 3D EX tD A22 IP67 T85°C
DIMENSIONS
RADIAL VERSION
L
14.5
12
4
4
X
14.5
10
TRIMMER
without trimmer
57
38
LED STABILITY
LED DI USCITA
61
14.5
10
CABLE VERSION
6.2
=
OUTPUT LED
STABILITY LED
OUTPUT LED
S5N-MR RADIAL VERSION
10 ... 30 Vdc (limit values)
2 Vpp max.
35 mA max.
N.O. and N.C.; PNP or NPN (short-circuit protection)
100 mA max.
2 V max.
0.5 ms (2 ms mod.F01/G00)
1 kHz (250 Hz mod.F01/G00)
OUTPUT LED (YELLOW) excluding mod.G00
STABILITY LED (GREEN) (mod.B01/C01/C21/E01/F01)
POWER ON LED (GREEN) (mod.G00)
sensitivity trimmer (mod.B01/C01/C21/E01/F01/T01)
-25 ... 55 °C
-25 ... 70 °C
500 Vac / 1 min. between electronic parts and housing
>20 M / 500 Vdc, between electronic parts and housing
B01: 0.1...2 m on R2
C01: 0...35 cm
red (630 nm) (mod. E01) / red (660 nm) (mod.B01/T01)
infrared (880 nm) (mod. C01/C21/G00)
according to EN 60947-5-2
11 ms (30 G) 6 shock for every axis (EN60068-2-27)
Nickel-plated brass
PMMA
IP67 Type 1 enclosure
M12 - 4 pole connector
60 g. max. connector vers.
SETTING
Setting of S5N-Mx...B01
Position the sensor and reflector on opposite sides.
Turn the sensitivity trimmer to the maximum position.
Moving the sensor both vertically and horizontally, determine the power on
and off points of the yellow LED (OUT) and then mount the sensor in the
middle of the points defined. Optimum operation is obtained when the
green LED (mod.B01) is ON and the yellow LED is OFF.
B01 models: If necessary reduce sensitivity in order to detect very small
targets. In order to improve alignment, repeat the procedure detailed
above whilst progressively reducing the sensitivity.
M O D E L S
with trimmer
without trimmer
Setting of S5N-Mx...C01
Turn the sensitivity trimmer to minimum: the green LED is ON, the yellow
L
79
69
X
43
38
LED is OFF. Position the target to detect in front of the sensor or of the
fibre terminals. Turn the sensitivity trimmer clockwise until the yellow LED
turns ON (Target detected state, pos.A). Remove the target, the yellow
mm
LED turns OFF. Turn the sensitivity trimmer clockwise until the yellow LED
turns ON (Background detected state, pos.B).
The trimmer reaches maximum if the background is not detected.
Turn the trimmer to the intermediate position C, between the two positions
10
A and B. The green LED must be ON.
STABILITY LED
Datalogic S.r.l.
Via S. Vitalino 13 - 40012 Calderara di Reno - Italy
Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com
Helpful links at www.datalogic.com: Contact Us, Terms and Conditions,
Support.
The warranty period for this product is 36 months. See General Terms
and Conditions of Sales for further details.
For information about the disposal of Waste Electrical
and Electronic Equipment (WEEE), please refer to the
website at www.datalogic.com.
©
2007
-
2019
Datalogic
RIGHTS RESERVED.  Without limiting the rights under copyright, no
part of this documentation may be reproduced, stored in or introduced into
a retrieval system, or transmitted in any form or by any means, or for any
purpose, without the express written permission of Datalogic S.p.A.
and/or its affiliates. Datalogic and the Datalogic logo are registered
trademarks of Datalogic S.p.A. in many countries, including the U.S.A.
and the E.U. All other trademarks and brands are property of their
respective owners. Datalogic reserves the right to make modifications
and improvements without prior notification.
821006311 Rev. B
A
C
B
MIN
MAX
S.p.A.
and/or
its
affiliates
ALL

Publicité

Table des Matières
loading

Sommaire des Matières pour Datalogic S5N-M Serie

  • Page 1 Via S. Vitalino 13 - 40012 Calderara di Reno - Italy Output saturation voltage: 2 V max. In case of lateral translation, the object must Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com Response time: 0.5 ms (2 ms mod.F01/G00) move as indicated in the figure.
  • Page 2: Manuale Istruzioni

    (880 nm) (mod. C01/C21/G00) Reiezione alla luce ambiente: come prescritto da EN 60947-5-2 © 2007 - 2019 Datalogic S.p.A. e/o le sue consociate  TUTTI I ampiezza 0.5 mm, frequenza 10 … 55 Hz, per ogni asse (EN60068-2-6) Vibrazioni: DIRITTI RISERVATI.
  • Page 3: Technische Daten

    Via S. Vitalino 13 - 40012 Calderara di Reno - Italy Schaltfrequenz: 1 kHz (250 Hz bei Mod. F01/G00) gem. nebenstehender Abbildung beachtet Tel: +39 051 3147011 - Fax: +39 051 3147205 - www.datalogic.com OUTPUT LED (gelb) ausgenommen Mod. G00 wird. Anzeigen: STABILITÄT LED (grün) bei Mod.
  • Page 4: Connexions

    10 … 30 Vdc SORTIE NO Type d'émission: infrarouge (880 nm) (mod. A00/C21/G00) © 2007 – 2019 Datalogic S.p.A. et/ou ses filiales  TOUS DROITS Réjection à la lumière ambiante: EN 60947-5-2 RÉSERVÉS.  Aucune partie de cette documentation ne peut être reproduite, 0.5 mm amplitude, 10 …...
  • Page 5: Physical Layer

    parameters PHYSICAL LAYER FEATURES Description Description Block Parameter IO-Link Revision Data Storage SIO Modus Min Cycle Time 5 ms (LED models) / 8 ms (Laser models) Parameter (write) access Supported Access Locks Data Storage Transmission Rate 38,4 kbit/s (COM2) PDInput: 24 Bit Process Data Length Device Profile: Smart Sensor PDOutput: 1 Bit...
  • Page 6 Lenght Value/Range Description Data Type Access* Remark (dec) Object Name (offset) 0x0010 (16) Vendor Name 9 octets DATALOGIC Informative StringT 0x0011 (17) Vendor Text 19 octets Empower your vision StringT 0x0012 (18) Product Name 15 octets Detailed product name StringT See “Device variant collection”...
  • Page 7 Teach-in Parameters Index Parameter Subindex Lenght Value/Range Description Data Type Access* Remark (dec) Object Name (offset) 0x00 = SSC1 (default, C/Q pin and DO C/Q and DO outputs are antivalent. 0x003A (58) TI Select 1 octet Selection for Teach-in channel (volatile) UIntegerT pin) Teach SSC1 equals to teach SSC2...
  • Page 8: Process Data

    Standard Command Index (dec) Command Name Lenght Value (dec) Description Access* Acquisition EASY (refer to User’s Manual) (M03, W03) / Teach Set Point (B01, C01, T01) 0x0002 (2) SP1 Single Value Teach 1 octet 0x41 (65) 0x0002 (2) SP1 Teach TP1 1 octet 0x43 (67) Acquisition FINE: Mark Detection (refer to User’s Manual) (W03)
  • Page 9: Eg-Konformität

    CE Compliance CE marking states the compliance of the product with essential requirements listed in the applicable European directive. Since the directives and applicable standards are subject to continuous updates, and since the manufacturer promptly adopts these updates, therefore the EU declaration of conformity is a living document. The EU declaration of conformity is available for competent authorities and customers through the manufacturer’s commercial reference contacts. Since April 20th, 2016 the main European directives applicable to the products require inclusion of an adequate analysis and assessment of the risk(s).

Ce manuel est également adapté pour:

S5n-maS5n-mr

Table des Matières