8
8
Rotate the inside casing until the nut is parallel to the axis of the pipe. Now raise the inside casing.
Pay attention that the sealing and surfaces are completely clean.
9
Place the retainer ring with connecting sealing and the O-sealing to the inside bushing.
10
Apply lubricant to the sealing surface of the crown.
11
Manually screw the screw-in crown head fi rst onto the inside casing.
Fix the retainer ring with the other hand.
12
12
Hold both installation wrenches as in picture above.
13
Ensure that the fi rst installation wrench grips on the ligament of the retainer ring.
This is for fi xing and will not be rotated.
14
With the second installation wrench, tighten the screw-in crown in.
15
The spacer on the retainer ring is used as a "torque limiter".
16
16
Check if the inside stopper is evenly on the pipe.
17
Check the sealing is installed correctly.
18
Apply lubricant to the connecting pipe and push into the screw-in crown up to the stopper.
19
If necessary, the connecting pipe can be adjusted horizontally or vertically about ± 7,5°.