Page 1
WebRunner USB V.90/V.92 56K Modem A01-PU3 MULTILANGUAGE Manual A01-PU3_MX01 Where solutions begin ISO 9001:2000 Certified Company...
Page 2
Italiano fare riferimento al sito www.atlantis- land.com. ENGLISH This product is covered by Atlantis Land 3 years On-Site warranty. For more detailed informations please refer to the web site www.atlantis- land.com. For more detailed instructions on configuring and using this device, please refer to the online manual.
Page 3
WARRANTY. Copyright The Atlantis Land logo is a registered trademark of Atlantis Land SpA. All other names mentioned mat be trademarks or registered trademarks of their respective owners. Subject to change without notice. No liability for...
1.4 Hardware Requirements ............20 1.5 Device Design .................21 1.6 Connecting The Modem To Your Computer ......22 1.7 Installing Your Modem Driver..........23 Windows XP/2000 ..............23 Windows Vista................23 Windows 98SE/ME..............23 1.8 Verifying Your Modem.............24 1.9 Uninstalling the WebRunner USB ...........25 1.10 Support .................25 A01-PU3...
Page 5
1.4 Besoins système ..............30 1.5 Device Design .................31 1.6 Installation Hardware ..............32 1.7 Installation des Pilotes sous Windows ........33 Windows XP/2000 ..............33 Windows Vista................34 Windows 98SE / ME..............35 1.8 Supprimer les drivers et l’utilitaire ...........36 1.9 Support ...................37 A01-PU3_MX01(V1.0 April 2007) A01-PU3...
Atlantis Land spa. Tutti i nomi di produttori e dei prodotti e qualsiasi marchio, registrato o meno, menzionati in questo manuale sono usati al solo scopo identificativo e rimangono proprietà...
Page 7
ITALIANO questo caso l’utilizzatore è responsabile della “compliance” con i limiti EMC. Il Produttore non è da ritenersi responsabile nel caso il prodotto sia utilizzato al di fuori delle limitazioni EMC. A01-PU3...
ITALIANO 1.1 Panoramica Atlantis Land Web Runner USB è il prodotto ideale per accedere in maniera semplice e funzionale alla rete PSTN. Il Web Runner USB è facile da installare e semplice da configurare, grazie al supporto Plug’n’Play per i sistemi operativi più...
Un PC con un connettore USB libero ed il controller USB correttamente installato • Microsoft Windows 98SE, ME,2000, XP o Vista • Almeno 10 MB di spazio libero sull’Hard Disk • Almeno Intel® Pentium® 233 Mhz o superiore con 128MB RAM con lettore CDRom A01-PU3...
Il modem non è alimentato Acceso Il modem è correttamente alimentato Spento Nessuna attività DATA Acceso Il modem sta inviando/ricevendo dati Collegare alla porta USB del PC LINE Utilizzare il cavo RJ11 fornito per la connessione alla linea telefonica A01-PU3...
Passare dunque all’installazione dei driver a seconda del Sistema Operativo utilizzato (si veda il paragrafo seguente). Accertarsi che la presa telefonica utilizzata sia di tipo analogico (la normale linea di casa); alcuni centralini utilizzano linee digitali che potrebbero danneggiare irrimediabilmente il modem. A01-PU3...
Reti e connessioni remote e crea nuova connessione. Scegliere poi l’opzione connessione ad Internet, poi imposta connessione manual ed infine tramite linea telefonica o modem. A questo punto scegliere il modem ed immettere poi i dati relativi alla connessione. A01-PU3...
(foto sotto), premere su Annulla Inserire il CDRom nell’apposito lettore e lanciare il file setup.exe (contenuto nella directory CDRom:\driver\USB\Win98SE oppure CDRom:\driver\USB\WinME). Seguire le istruzioni a video per completare l’installazione. Cliccare su OK per iniziare l’installazione. A01-PU3...
(con tutti i relativi comandi AT e le impostazioni della porta seriale cui il WebRunner USB è collegato). Nel caso la videata risulti vuota, oppure il programma di diagnostica non riesca a individuare o dialogare col modem, rimuovere la periferica e ripetere l’installazione da capo. A01-PU3...
Per qualunque altro problema o dubbio (prima è necessario conoscere tutti i parametri usati dall’ISP) è possibile contattare l’help desk telefonico (02/93907634) gratuito di Atlantis Land che fornirà assistenza da lunedì al giovedì dalle 9:00 alle 13:00 e dalle 14:00 alle 18:00. Il venerdì dalle 9 :00 alle 13 :00.
Page 16
ITALIANO Viale De Gasperi 122 20017 Mazzo di Rho(MI) Tel: 02/93907634(help desk) Fax: 02/93906161 Email: info@atlantis-land.com oppure tecnici@atlantis-land.com (mettere nell’oggetto il codice del prodotto di cui si chiede assistenza) WWW: http://www.atlantisland.it o www.atlantis-land.com A01-PU3...
Page 17
Windows™ 98SE/2000/ME/XP are trademarks of Microsoft® Corp. Pentium is trademark of Intel. All copyright reserved. The Atlantis Land logo is a registered trademark of Atlantis Land SpA. All other names mentioned mat be trademarks or registered trademarks of their respective owners.
• Support V.92 (up to 56 Kbps download, 48 Kbps upload) • Modem on Hold (V.92) and Quick Connect (V.92) • Data Compression V.44/V.42 bis/MNP 5 • Hot Plug and Play 98/98SE/ME/2000/XP/Vista • No external power supply is required. A01-PU3...
• Microsoft Windows 98SE, ME,2000, XP or Vista • At least 10MB of free disk space for the driver and software • Intel® Pentium® 233 Mhz or compatible processor with 128MB RAM with CDRom drive A01-PU3...
POWER No power is supplied to the device Steady light Power is detected No activity DATA Steady light Data is being transmitted/received Used for connecting to the computer LINE Used for connecting to the telephone line via telephone cable A01-PU3...
LINE jack on Modem and the other end to your Telephone Wall Socket. Connect the USB cable of the Modem to the USB port on your computer. This completes the modem connections. Please proceed to driver/utility installation. A01-PU3...
Click Continue (An program needs your permission to continue), then click OK (2 times) in order to complete installation. Windows 98SE/ME Place the Installation CD into your CDRom Drive. If You want install immediately driver, click setup (CDRom:\Driver\USB\Win98SE\setup.exe CDRom:\Driver\USB\WinME\setup.exe ) to continue. Installation will start automatically. A01-PU3...
The V.92 Feature Setting application provides control over various V.92 features. When launched you will see the V.92 Feature tab. This tab provides the ability to enable/disable Quick Connect as well as to clear the Quick Connect memory. When you click on the Clear Data button A01-PU3...
If you continue to have problems you should contact the dealer where you bought this device. If you have any other questions you can contact the Atlantis Land company directly at the following address: Atlantis Land SpA Viale De Gasperi, 122 20017 Mazzo di Rho(MI) Tel: +39.
Page 26
à l’utilisation de notre manuel logiciel et/ou disque dur. Toutes les marques ou noms de produits mentionnés dans le présent manuel sont des marques commerciales et/ou brevetées par leurs propriétaires respectifs. A01-PU3...
Page 27
FRANCAIS Marquage CE Cet appareil, qui appartient à la Classe B peut causer des interférences radio, dans ce cas nous vous invitons à prendre les contre-mesures appropriées. A01-PU3...
Une fois ouverte, vous devriez trouver les éléments suivants: • WebRunner USB ™ • CD avec pilotes, manuels et NetWaiting • Guide d'installation • Câble téléphonique (RJ11) • Coupon de Garantie Si vous constatez qu’un de ces composants manque, merci de vous adressez à votre revendeur. A01-PU3...
PC desktop ou portable avec un slot USB 1.1 libre • Système Windows 98SE, ME, 2000, XP ou Vista • 10MB d’espace libre sur disque dur • Processeur Intel® Pentium® 233 Mhz ou compatible et 128 Mo de mémoire vive ou plus avec Lecteur CDRom A01-PU3...
Le WebRunner n’est pas actif Allumée Le WebRunner est actif La connexion n’est pas active DATA Allumée Données en cours de transfert Pour la connexion au port USB de l’ordinateur LINE Connexion à la prise téléphonique avec le câble RJ11 fourni A01-PU3...
USB de l’ordinateur, une nouvelle fenêtre apparaîtra. Cliquez sur Annuler. Raccordez le câble téléphonique (fourni) sur votre ligne téléphonique. S'assurer que la prise téléphonique utilisée soit de type PSTN analogique, ligne ISDN (RNIS) peut endommager le modem. A01-PU3...
Suivant. Dans la prochaine fenêtre, cochez la ligne en utilisant ma ligne téléphonique et un modem et cliquez sur Suivant. Saisissez le numéro d'appel composé par votre modem dans le champ Numéro de téléphone et cliquez sur Suivant. Saisissez alors votre Nom A01-PU3...
Internet. • WinVista : Cliquez sur Démarrer, puis sélectionnez Panneau de configuration. Double-cliquez sur Centre Réseau et partage et cliquez sur Configurer une connexionou un réseau. Vous arrivez sur la page d'accueil de l'Assistant Nouvelle Connexion, cochez sur A01-PU3...
Dans la prochaine fenêtre, dans le champ Entrez un nom pour l'ordinateur appelé, entrez le nom de votre choix. Par défaut votre modem s'affiche dans le champ Sélectionnez un périphérique : ne changez rien. Cliquez ensuite sur Suivant. Saisissez le numéro A01-PU3...
Modifier un programme) qui s'affiche, sélectionnez Conexant UCM92 Data Fax RTAM USB Modem. • Cliquez sur le bouton Modifier/Supprimer (Désinstaller/Modifier). Le programme d'installation supprimera les pilotes du modem. Cela peut prendre quelques minutes. • Débranchez les câbles du modem pour terminer. A01-PU3...
Pour tous problèmes ou renseignements (il est IMPERATIF de connaître au préalable les paramètres utilisés par le FAI), vous pouvez contacter la « help desk » téléphonique gratuite d’Atlantis Land qui vous fournira assistance du lundi au jeudi de 9.00 à 13.00 et 14.00 à 18.00, le vendredi de 9.00 à...
Page 37
Atlantis Land S.p.A. Viale De Gasperi, 122 Mazzo di Rho – MI – Italy info@atlantis-land.com sales@atlantis-land.com www.atlantis-land.com Where solutions begin...