Incandescent / Halogen 120 V Dimmer
Rated at 120 V~ 60 Hz; 600 or 1000 Watt (depending on model).
Important Notes
Please read before installing.
1. CAUTION: Use only with permanently-installed 120 V incandescent or halogen fixtures. To avoid
overheating and possible damage to other equipment, do not use to control receptacles, fluorescent
lighting fixtures, motor-driven appliances, or transformer-supplied appliances.
2. Install in accordance with all national and local electrical codes.
3. Only one dimmer can be used in a 3-way circuit.
4. When no "grounding means" exist within the wallbox then the NEC
dimmer without a grounding connection to be installed as a replacement, as long as a plastic,
noncombustible wallplate is used. For this type of installation, cap or remove the green ground wire on
the dimmer and use an appropriate wallplate such as Lutron's Claro
5. For new installations, install a test switch before installing the dimmer.
6. Protect dimmer from dust and dirt when painting or spackling.
7. Recommended minimum load is 40 Watts
8. It is normal for the dimmer to feel warm to the touch during operation.
9. Clean dimmer with a soft damp cloth only . Do not use any chemical cleaners.
Multigang Installations
When installing more than one control in the
same wallbox, it may be necessary to remove
all inner side sections prior to wiring (see
below). If pre-installed, remove the Lutron
wallplate and wallplate adapter from dimmer.
Using pliers, bend side section up and down
until they break off. Repeat for each side section
to be removed. Removal of dimmer side
sections reduces maximum load capacity. Refer
to chart below for maximum dimmer capacity.
Each Control Has Inside
Dimmer Capacity Chart
Dimmer
No sides
Rating
removed
600 W
600 W max.
1000 W
1000 W max.
Technical Assistance
?
If you have questions concerning the installation or operation of this product, call the
Lutron Technical Support Center . Please provide exact model number when calling.
U.S.A. and Canada (24 hrs/7days)
+1-800-523-9466
Other countries 8am – 8pm ET
+1-610-282-3800
Limited Warranty
(Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.)
Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service,
return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS WARRANTIES, AND THE IMPLIED WARRANTY OF MERCHANTABILITY IS LIMITED
TO ONE YEAR FROM PURCHASE. THIS WARRANTY DOES NOT COVER THE COST OF INSTALLATION, REMOVAL OR REINSTALLATION,
OR DAMAGE RESULTING FROM MISUSE, ABUSE, OR DAMAGE FROM IMPROPER WIRING OR INSTALLATION. THIS WARRANTY DOES NOT
COVER INCIDENTAL OR CONSEQUENTIAL DAMAGES. LUTRON'S LIABILITY ON ANY CLAIM FOR DAMAGES ARISING OUT OF OR IN
CONNECTION WITH THE MANUFACTURE, SALE, INSTALLATION, DELIVERY, OR USE OF THE UNIT SHALL NEVER EXCEED THE
PURCHASE PRICE OF THE UNIT.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state. Some states do not allow the exclusion
or limitation of incidental or consequential damages, or limitation on how long an implied warranty may last, so the above limitations may not apply
to you.
This product may be covered by one or more of the following
U.S. patents: 4,835,343; 4,835,816; 4,947,054; 5,207,317;
5,262,678; 5,359,231; 5,637,930; 6,005,308; D342,234;
D364,141 and corresponding foreign patents. Lutron,
Ariadni, Diva, Glyder, Luméa2, and Skylark are registered
trademarks of Lutron Electronics Co., Inc. NEC is a
registered trademark of the National Fire Protection
Association, Quincy, Massachusetts.
© 2005 Lutron Electronics Co., Inc.
Lutron Electronics Co., Inc.
7200 Suter Road
Coopersburg, PA 18036-1299, U.S.A.
Made and printed in U.S.A.
12/05 P/N 030-635 Rev. F
Ariadni
Luméa2
®
®
Diva
Rotary
®
Glyder
Skylark
Installation
®
®
1
2
2002, Article 404-9 allows a
®
or Fassada
series wallplates.
®
TM
3
Do Not Remove
Outside Sections
Middle Control Has Two
SINGLE-POLE:
Sections Removed
Side Sections Removed
Insulated wires connected
to two screws of the same
1 side
2 sides
color. Replace with a
removed
removed
SINGLE-POLE dimmer.
500 W max.
400 W max.
See Step 5a.
800 W max.
650 W max.
4
Fax +1-610-282-3090
http://www.lutron.com
Important Wiring Information
When making wire connections, follow the recommended strip lengths and
combinations for the supplied wire connectors. Note: Wire connectors provided are
suitable for copper wire only. For aluminum wire, consult an electrician.
030-635
030-635
Turning OFF power.
• Turn power OFF at circuit breaker (or remove fuse).
Removing wallplate and switch.
• Remove wallplate and switch mounting screws.
• Carefully remove switch from wall (do not remove wires).
Caution: Verify power
is OFF to switch
before proceeding.
Identifying the type of circuit.
Different-colored screw
(Common). Actual location may
vary.
OR
Ground (Bare
Copper or
Green Wire)
Ground (Bare Copper
or Green Wire)
Tag
3-WAY:
Insulated wires connected to three screws. One
of these wires is connected to a screw of a
OR
different-color (not green) or labeled COMMON.
MARK or TAG this wire to identify it when wiring.
Replace with a 3-WAY dimmer. See Step 5b.
Disconnecting switch wires.
• Carefully disconnect switch wires.
Screw Terminals:
Turn screws to
loosen.
Small:
Strip insulation 3/8" (10 mm) for 14 AWG wire
Strip insulation 1/2" (13 mm) for 16 or 18 AWG wire
Use to join one 14 AWG supply wire with one 16 or
18 AWG control wire.
Large:
Strip insulation 1/2" (13 mm) for 10, 12 or 14 AWG
wire
Strip insulation 5/8" (16 mm) for 16 or 18 AWG wire
Use to join one or two 12 or 14 AWG supply wires
with one 10, 12, 14, 16, or 18 AWG control wire.
Large
Small
5
Wiring the Dimmer.
• For installations involving more than one control in a wallbox, refer to
the section on Multigang Installations before beginning.
Note: Wire location will vary by product. Reference wires by color, not
location.
5a - Single-Pole Wiring
Black
Ground
Green
Black
Black
Green
120 V~
60 Hz
Light
Ground
5b - 3-Way Wiring
Tag
Black
Green
Ground
Red
Black
Red
Green
Red
120 V~
Dimmer
3-Way Switch
60 Hz
Ground
Light
6
Mounting dimmer to wallbox.
Backwired:
Insert
• Form wires carefully into the wallbox, mount and align dimmer.
screwdriver.
• Install wallplate.
Pull wire out.
Start screws.
Note: To install a traditional
Glyder
®
style wallplate, firmly pull
the Glyder
or Rotary knob
®
to remove it. Install the
wallplate and re-attach the
knob.
7
Turning ON power.
• Turn power ON at circuit breaker (or replace fuse).
• Connect the green dimmer
ground wire to the bare copper or
green ground wire in the wallbox.
(See Important Note 4.)
• Connect one of the black dimmer
wires to either of the wires
removed from the switch.
• Connect the remaining black
dimmer wire to the other wire
removed from the switch.
Note: To use a 3-Way dimmer in
a single-pole application, cap off
one of the red wires and follow
instructions for single-pole wiring.
(If the on/off switch works
backwards, switch the red wires.)
• NOTE: Only one dimmer can be
used in a 3-WAY circuit.
• Connect the green dimmer
ground wire to the bare copper or
green ground wire in the wallbox.
(See Important Note 4.)
• Connect the black dimmer wire to
the wire removed from the
different-colored screw on the
switch (marked or tagged wire).
Remove tag from wire.
• Connect one of the red dimmer
wires to either of the remaining
wires removed from the switch.
• Connect the remaining red
dimmer wire to the remaining wire
removed from the switch.
Align dimmer and
tighten screws.
Rotary

Publicité

loading

Sommaire des Matières pour Lutron Ariadni

  • Page 1 (Valid only in U.S.A., Canada, Puerto Rico, and the Caribbean.) Lutron will, at its option, repair or replace any unit that is defective in materials or manufacture within one year after purchase. For warranty service, return unit to place of purchase or mail to Lutron at 7200 Suter Rd., Coopersburg, PA 18036-1299, postage pre-paid.
  • Page 2 En raccordant des fils, respecter les longueurs et les combinaisons de dénudation recommandées Lutron, à son choix, réparera ou remplacera toute unité présentant des défauts de matériaux ou de main-d’œuvre pendant une durée de un (1) an pour les capuchons de connexion fournis. Remarque : N’utiliser que des fils de cuivre avec les à...