Pre-Operation; Nozzle Maintenance; After Operation - Wilks USA RX510 Mode D'emploi

Nettoyeur haute pression électrique
Masquer les pouces Voir aussi pour RX510:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

RX510
Pre Operation
The angle of spray coming out of the variable nozzle
may be adjusted by rotating the variable nozzle. This
will vary the spray pattern from a 0° narrow high
impact to 60° wide spray.
Adjusting the spray pattern
With a narrow stream you get a high impact force
and this results in maximum deep cleaning in a
concentrated area. However, this narrow high impact
spray must not be used cautiously, as it may damage
some surfaces.
Narrow high impact stream
A wide spray pattern will distribute the impact of the
water over a larger area, resulting in excellent cleaning
action with a reduced risk of surface damage. Large
surface areas can be cleaned more quickly using a
wide spray pattern.
Wide angle spray pattern
En

Nozzle Maintenance

A clogged or partially clogged nozzle can significantly
reduce water flow and cause the unit to pulsate while
spraying. To clean the nozzle:
1. Turn off and unplug the unit from the electric mains.
2. Turn off the water supply and relieve any pressure
trapped in the hose by squeezing gun trigger 2-3
times.
3. Separate lance from gun.
4. Rotate the nozzle to the narrow high impact stream
setting. This opens up the fan blades.
5. Using the included tip cleaner, or an unfolded paper
clip, insert the wire into the nozzle hole and move
back and forth until any debris is dislodged.
6. Remove additional debris by back-flushing water
through the nozzle. To do this, place end of a
garden hose (with water running) to end of nozzle
for 30-60 seconds.
Insert tip cleaner into the nozzle hole and
move back and forth until debris is dislodged

After Operation

Do not store the pressure washer outdoors or in a
location where it may freeze. Any water left in the
machine, gun or any other components will expand if
allowed to freeze, causing damage.
Always turn the motor off before turning the water
supply off.
Never disconnect the hose from machine while the
system is pressurized. To de-pressurize, turn the
motor off, then turn the water supply off and squeeze
gun trigger 2-3 times.
© Wilks-USA
4

Publicité

Table des Matières
loading

Table des Matières