SECTION 5. OPERATING INSTRUCTIONS
Switch hood power on at the fused spur.
Pushbutton Functions
Motor RUN ON TIMER
(OFF after 10 minutes to clear fumes)
Motor ON –INTENSIVE MODE
(Reverts to speed 3 after 5 minutes *)
Motor ON - SPEED 3
(Maximum Speed for Normal Use)
Motor ON - SPEED 2
Motor ON - SPEED 1
The extractor controller will automatically switch off
the appliance if there has been no operator action for
4 hours.
After 30 hours accumulated running the GREASE FILTER
CLEANING reminder will be signalled by all 6 pushbutton
indicators flashing. Reset the filter cleaning timer by
pressing the RUN ON TIMER Pushbutton.
* The automatic speed reduction feature is required by UK
& EU Ecodesign and Energy Labelling legislation.
For the best extraction performance, you are advised to
switch the extractor on at least 5 minutes before cooking
commences.
SECTION 6. MAINTENANCE
Regular maintenance is essential to ensure good
performance and long-life.
To maintain the immaculate appearance of the extractor,
and to minimise fire risk, ensure that grease deposits on
the extractor surfaces are kept to a minimum by regular
cleaning.
To clean the stainless-steel surfaces of the extractor, use
a soft cloth and a suitable cleaning agent, such as a
specially produced stainless-steel cleaner or washing up
detergent and warm water.
To avoid spoiling the finish of brushed stainless-steel
surfaces you should always wipe along the grain (in the
direction of the brush lines); wiping across the grain can
mark the metal.
 Do not use abrasive cleaning materials or abrasive
cleaning products and chemicals on any hood
surfaces.
 Do not use any bleach-based cleaning products on
any hood surfaces.
Aga Rangemaster FM900
Motor OFF
Lights ON/OFF
W0645 Aga Rangemaster FM900 (energy label version) O&M Dec 21.docx
Clean the grease filters in a dishwasher or by hand-
washing in hot water and detergent. Wash the filters at
least every 2 months - sooner if the extractor is used
extensively and filters become grease laden.
Whilst you can expect years of service from your grease
filters, they are considered a consumable item and may
deteriorate over time and need replacement, particularly
when cleaned in a dishwasher.
For all users, filters should be replaced whenever they
exhibit signs of physical wear.
To remove the grease filters, pull the filter release lever
away from the hood base, releasing the sprung latch,
allowing the filter to be lifted away from the hood. Care
should be taken not to scratch the hood.
LED lamps require no end user maintenance.
SECTION 7. SPECIFICATIONS
Blower airflow, nominal:
(In free air without ducting)
Supply voltage:
LED lamp voltage:
Blower power input:
Lamp power:
Fuse size for electrical supply:
Duct spigot diameter:
Approximate Weight
For
detailed
specification
information please refer to the product fiche for your hood.
3
800 m
/hr
220-240V~ 50Hz
12V
275 W
2 x 2.6 W
3A
150 mm
11 Kg
and
energy
efficiency
5