TROUBLE
Poor Spray Pattern
Battery will not Charge.
TROUBLESHOOTING
LOOK FOR
1. Tank is not pressurized.
2. Nozzle partially clogged.
3. Nozzle damaged.
4. Shut-off clogged.
1. Charger not plugged into
outlet.
2. No lights illuminated on Pump.
Charger plugged into outlet.
3. No lights illuminated on Pump.
Charger plugged into outlet,
outlet functioning.
4. Red light continues flashing on
Pump (Battery temperature too
high for safe charging).
5. Red and Green lights flash
alternately on Pump (Battery can-
not be charged).
REMEDY
1. Turn on Pump.
2. Clean Nozzle. See Nozzle
Maintenance.
3. Replace Nozzle.
4. Clean Shut-off. See Shut-off
Maintenance.
1. Plug Charger into outlet.
2. Check that outlet is function-
ing.
3. Replace Charger.
4. Allow Pump to cool.
5. Replace Pump.