If you are going to store your generator for more than 30
days, use the following information as a guide to prepare
the generator for storage.
STORAGE INSTRUCTIONS
CAUTION: Never store generator with fuel in the
tank indoors or in enclosed, poorly ventilated areas,
where fumes can reach an open flame, spark or pilot
light as on a furnace, water heater, clothes dryer or
other gas appliances.
Engine Preparation
• Add fuel stabilizer to fuel tank to minimize the
formation of fuel gum deposits during storage.
• Run engine at least 10 minutes after adding stabilizer
to allow it to enter the fuel system.
• Next shut off engine.
PROBLEM
Engine will not start
No electrical output
Repeated circuit breaker tripping
Generator overheating
DC does not have power with the
circuit breaker depressed
TROUBLESHOOTING GUIDE
TROUBLESHOOTING GUIDE
CAUSE
1. Low on fuel or oil.
2. Ignition switch in "Off" position.
3. Faulty spark plug.
4. Choke in wrong position.
5. Fuel shut-off valve in closed
position.
6. Unit loaded during start-up.
7. Spark plug wire loose.
1. Faulty receptacle.
2. Circuit breaker kicked out.
3. Defective capacitor.
4. Faulty power cord.
5. GFCI switch breaker kicked out (if
equipped)
1. Overload
2. Faulty cords or equipment.
1. Generator overloaded.
2. Insufficient ventilation.
1. Faulty rectifier
2. Faulty windings in stator
3. Faulty wire harness
15 — ENG
• Disconnect the spark plug wire and remove the
spark plug.
• Add one teaspoon of oil through the spark plug hole.
• Place rag over spark plug hole and pull the recoil a
few times to lubricate the combustion chamber.
• Replace the spark plug, but do not connect the spark
plug wire.
NOTE: If a fuel stabilizer is not used, all gasoline must
be drained from the tank and carburetor to prevent gum
deposits from forming on these parts and causing
possible malfunction of the engine.
Generator
• Clean the generator as outlined on Page 13 (Generator
Maintenance)
• Check that cooling air slots and openings on generator
are open and unobstructed.
1. Add fuel or oil.
2. Turn to "ON" position
3. Replace spark plug.
4. Adjust choke accordingly.
5. Open fuel shut-off valve.
6. Remove load from unit.
7. Attach wire to spark plug.
1. Have Service Center replace.
2. Depress and reset.
3. Have Service Center replace
capacitor.
4. Repair or replace cord.
5. Depress and reset.
1. Reduce load.
2. Check for damaged, bare, or
frayed wires on equipment.
Replace.
1. Reduce load.
2. Move to adequate supply of
fresh air.
1. Have Service Center replace.
2. Have Service Center replace.
3. Have Service Center replace.
CORRECTION