GREASE (free of resins and
acids)
Designation in accordance
with DIN 51502
Consistency class (DIN 51818)
Saponification type
Dripping point
Worked penetration
Temperature range
Oiler types used on or with our tools:
26
All manuals and user guides at all-guides.com
Multi-purpose greases for
antifriction and friction
bearings
K L 2 k
2
Lithium
185 °C
265 to 295
-25°C to + 125°C
Oiler to mount on the machine or connect in the hose line
Setting the oiler: The adjustment screw item 2 is visible after
removing the screw plug item 3. Theoil supply is decreased by
tightening the screw, and by loosening the screw, more oil gets into
the machine. In most cases it is sufficient to tighten or loosen the
screw by ¼ or ½ of a turn. When plugged, clean borehole (dia. 2
Correct setting; When under pressure and with the filler screw (item
The fillint lasts for approx. 8 operating hours.
For stationary pneumatic machines and motors, the lubrication is
carried out by lined-up oilers for horizontal or vertical installation.
Setting of oilers: Shut off air supply. Open plug item 3.
Loosen visible lock nut item 5 with a socket wrench.
Using a screw driver turn back the tightened screw plug item 4 by ¼
No oil is to get into the borehole "a" when filling. Close plug item 3
Correct setting: A piece of paper held for a short time in front of the
outlet must be coated with oil without drops forming.
For installing in permanently equipped workplaces
(especially for type using service units – see accessories list)
The transparent supply containers allow for good
checking as well as for good setting possibility by
means of a screw driver via a set screw with visible
dripping. (The set screw is above the lateral thread
connection – turning to the right for less oil; turning to
the left for more oil) The setting (2 to 5 drops per
m³/min air consumption) is to be carried out when air is
flowing through, i.e., when the machine is running.
Special greases for high-speed
-25°C bis + 100°C
mm) with wire.
4) open, the oil must bubble slightly.
Line oiler
to ½ of a turn and then lock again.
and open the air supply.
Transparent oiler
miter gears
G 000 h
00
Sodium
145°C
400 bis 410