Ø ELECTRICAL CONNECTION
The appliance must be properly installed and grounded by a qualified technician in accordance, with the
National Electrical Code ANSI / NFPA No. 70 (Latest Edition) and local electrical code requirements.
Installation should be made by a licensed electrician.
The appliance may be connected by means of permanent "Hard Wiring" or "Power Supply Cord Kit".
The cooktop must be connected to the proper electrical voltage and frequency as specified on the rating
label. Note: Unit must be connected to an independent 20 Amp circuit.
The cooktop can be connected directly to the fused disconnect (or circuit breaker box) through flexible,
armored or non-metallic sheathed, copper cable (with grounding wire). Allow two to three feet of slack in
the line so that it can be moved if servicing is ever necessary.
FOR PERSONAL SAFETY, THE COOKTOP MUST BE PROPERLY GROUNDED.
Remove house fuse or open circuit breaker before beginning installation.
Do not attempt to repair or replace any part of the appliance unless it is specifically recommended in this
manual. All other servicing should be referred to a qualified technician.
To minimize the possibility of electric shock, disconnect this appliance from the A/C power supply before
attempting any maintenance.
NOTE: Turning the appliance off does not disconnect the appliance from the power
supply. We recommend having a qualified technician service your appliance.
INSTALLATION MUST BE DONE BY A LICESNSED PROFESSIONAL
1. Disconnect Main Power Supply
2. Remove junction box cover, if present.
3. Connect the flexible cable conduit from the cooktop to the junction box using a UL listed or
CSA approved conduit connector.
4. Tighten screws on conduit connector, if present.
5. Connect the two L2 wires together using the UL listed wire connectors
6. Connect the two L1 wires together using the UL listed wire connectors
7. Connect the Ground (G) or bare ground wire from the cooktop cable to the Ground (G) or bare
ground wire (in the junction box) using UL listed wire connectors.
8. Install junction box cover
9. Reconnect power.
WARNING
A – 3-wire cable from the
main power supply
B – L1 Wires
C – Ground (G) or bare
ground wire (from
cooktop)
D – 3-Wire cable from the
cooktop
E – Junction Box
12
F – Neutral wire
(from power supply)
G – UL listed wire connector
H – L2 wires
I – UL listed or CSA approved
conduit connector