Installer Set Options

The installer can set different options for the system to customize the installation. The options listed
below show the regular settings and have an area or check box to note custom settings.

Siren Run Time

If there is a burglary, panic (police), or emergency alarm, the Control Panel will sound the siren for a preset
time. After the time expires, the siren will stop sounding. (Auxiliary alarms run for an unlimited time.)
❑ 4 Minutes (regular setting)

Sensor Trigger Limit

The system limits the number of times a sensor can re-trigger an alarm while the system is armed.
The setting is one to six times per sensor, per arming period.
❑ 1 Trigger
❑ 2 Triggers (regular setting)

Fire Horn Run Time

If there is a fi re or carbon monoxide alarm, the Control Panel will sound the fi re alarm horn for a
preset time. After the time expires, the fi re alarm horn will stop sounding.
❑ 4 Minutes (regular setting)

Exit Delay

The Exit Delay begins immediately after arming the system. The delay gives you time to leave through
the designated exit/entry door without setting off the alarm. During the Exit Delay beeps sound, and
faster beeps sound during the last 10 seconds. (NOTE: Arming remotely does not start an Exit Delay).
❑ 60 Seconds (regular setting)

Entry Delays

The Entry Delay begins when the designated entry/exit door is opened while the system is armed.
The delay gives you time to disarm the system before triggering the alarm. You must enter a User
Code on the Control Panel or Wireless Keypad before the Entry Delay time expires. During
the Entry Delay, beeps sound to remind you to disarm the system.
The system supports two different Entry Delays. Entry Delay #1 is for your primary entrance door;
Entry Delay #2 is for a secondary entrance (such as a garage door) and is usually set longer to give
you time to get to the keypad and disarm the system.
❑ 30 Seconds (regular setting)
❑ 45 Seconds (regular setting)

24-Hour Emergency Functions

Three 24-hour emergency functions: PANIC, FIRE, and EMERGENCY can be activated by buttons on
the Control Panel. The installer can set which emergency buttons on the Control Panel are active.
ACTIVE CONTROL PANEL EMERGENCY BUTTONS
❑ Audible Panic
❑ Silent Panic
42
SIREN RUN TIME
❑ 8 Minutes
❑ 12 Minutes
SENSOR TRIGGER LIMIT
❑ 3 Triggers ❑ 4 Triggers ❑ 5 Triggers ❑ 6 Triggers
FIRE HORN RUN TIME
❑ 8 Minutes
❑ 12 Minutes
EXIT DELAY
_________ Seconds
ENTRY DELAY #1
_________ Seconds
ENTRY DELAY #2
_________ Seconds
❑ Fire
❑ 16 Minutes
❑ Unlimited
❑ 16 Minutes
❑ Unlimited
For _______________ Door
For _______________ Door
For _______________ Door
❑ Emergency

Publicité

Table des Matières
loading

Table des Matières