Gas Atmospheres (Can & US)
Class I, Div. 1, Groups B, C & D, T6
Class I, Zone 1, AEx db, Group IIB+H
Ex db, Group IIB+H
o
-50
C ≤ T
amb
(Thermostats with base housing option 3, conduit mount,
are certified to Groups C,D and IIB only.)
Dimensions
(wall mount thermostat)
Specifications
Temperature adjustment range is 5
Temperature differential (hysteresis) = +/- 1
Electrical Ratings: 22 Amp up to 480VAC, 50/60 Hz;
1/2HP @ 125VAC; 1HP @ 250VAC
PILOT DUTY: 490 VA @ 125VAC, 800 VA @ 250VAC
Storage temperature: -50
SPDT for heating or cooling applications.
Routine Maintenance
For optimal operation remove excess dust / debris using compressed air.
Ensure all field wiring connections are secure and free of excess wear.
Ensure all stopping plugs, blanking elements, and fittings are tight and
secure.
Printed in Canada
Bi-Metal Thermostat
Installation and Maintenance Manual
Hazardous Location Ratings
, T6, Gb
2
, T6, Gb
2
o
≤ +40
C, IP66, Type 4
o
o
o
C to 25
C (40
F to 80
o
C (+/- 1.8
o
o
o
o
C to +60
C (-58
F to 140
Dust Atmospheres (Can & US)
Class II, Div. 1, Groups E, F & G
Class II, Div. 2, Groups F & G: Class III, T6
And
Class II, Zone 21, AEx tb, Group IIIC, T85
-50
BTX1 - N - ?
Option "1" - Wall Mount, see figure 1.
Option "2" - Y-mount, see figure 2.
Option "3" - Conduit Mount, see figure 3.
o
F).
o
F) from set point.
F).
Temperature set point can be locked via the set
screw located behind the pointer. Use a 5/64"
allen key to lock / unlock the set screw.
Rotate the temperature adjustment knob until the
desired set temperature is indicated by the pointer.
Thermostat is factory calibrated. Thermostat
cannot be calibrated in the field.
o
Ex tb, Group IIIC, T85
C, Db
o
o
C ≤ T
≤ +40
C, IP66, Type 4
amb
BTX1 Model Coding
Product Rev. No
Factory Assigned
For minor revisions
Certification
N
Model Series
Base Housing Option Codes
Figure 1
Figure 2
Operation
Part No. BTX1-OM-N-A-E_F
o
C, Db
.
CSA - Can / US
Figure 3