PHAROS 100W
RGBW/ Dynamic white 108W
1. Function
Powerful, compact floodlight for. architectural
lighting as well as large external areas. Thanks to
the multitude of beams available it can also be
used in many cases where a large scope of lighting
is needed or on the contrary for linear lighting,
such as for example around industrial buildings to
light access roads
Characteristics
Construction/special Functions available on
request.
2. Technical data/Assembly
·
Floodlight on moveable head with 40 700mA LED
cold white (6000 K), neutral white (4500 K), warm
white (3000 K), RGBW/WWWW 18*6w
360° rotating
Diffusion of light by rotational symmetry of 10° and
25° and 40° for LEDS
316L stainless steel gland
Delivered with 1m submersible cable
3. ·
Installation/assembly
·
Please comply with the applicable national safety
requirements. We disclaim all responsibility for non-
compliant use or assembly. Similarly, we reject any
responsibility for any modifications to the light fittings.
When in use, constant current spotlights must always
be connected in series to the corresponding DC power
supply (see power packs) (350/700 mA).
Do not disassemble the spotlight casing, because the
cables and the plate are sealed.
The spotlight can be installed in concrete, paving
blocks, plates, wood. We cannot supply universal
installation instructions because ground conditions
and the location will vary for each project. The
pictograms show examples of typical installations A/B /
C
Assembly:
When mounting on a reinforced bracket, you must remove the
screws; remove the projector from its support and turn it
toward the object to be lit. Then fix to the bracket using the A4
stainless steel screws provided. (D/E/F)
Caution: Use only the factory-connected cables. Please
indicate the required cable length when ordering. In the event
of mechanical stress, the cable must be installed in a
protective conduit.
The connection of the silicone cable to the supply must be
carried out in a dry environment and, in the event of a direct
connection in the ground, only connection units compatible
with a joint sealing compound should be used. (E.g. IP68-1)
Connect the various conductors to power supplies in
accordance with instructions. The maximum number of lights
that can be connected is indicated in the power pack manual
(see catalogue)
4.
Connecting to the power packs/connection matrix
Constant current spotlights must only be connected in
series. H/I. If applicable, proceed with connection in series
in separate load distribution units, the outside of which
must also be protected against humidity using a sealing
compound.
5.General Maintenance Instructions
When cleaning the spotlight, do not use detergents which are
harmful to metals. The use of hydrochloric acid-based
detergents on and around any parts of a stainless steel light
fitting is totally prohibited. Regularly clean the spotlight and its
mounting box to avoid any rust deposit
Caution: Do not use a high-pressure cleaner.
-
Any lost screws should only be replaced by V4A
stainless steel screws.
-
According to requirements (power, environmental
circumstances), it is recommended to change the seals (on the
glass, screw fittings and O-rings) and the cable every 5 to 8
years.
6. Warranty conditions
The following time limits and provisions of the warranty shall
apply from the date of delivery: - 24 months for Orsteel
spotlights
•The warranty covers defects in materials, construction defects
and any treatment proven to be attributable to the
manufacturer.
•Any damage resulting from the non-compliance with this user
leaflet or any non-compliant repair is excluded from the
warranty.
•We disclaim any guarantee where the installation has not
been carried out according to the instructions or where
unsuitable bulbs or connection cables have been used.
•We reserve the right to make any modification corresponding
to technical development.
7. Important Notes
(The warranty becomes void in the event of
non-compliance with the following points)
•The absence of damage caused during transport must
be verified before installation!
•All assembling and installation, as well as any electrical
work, must be carried out by qualified personnel.
•To avoid any deposit of rust, stainless steel tools only
should be used!
•The cable length for lamps must be chosen to avoid
extending it in water or in a wet environment. Any
subsequent claim for this reason will not be accepted.
•A mounting distance of 10 cm between each device is
strongly recommended to avoid mutual heating.
•Equipment must not be connected to the electricity
supply during installation, otherwise surges in the power
supply could damage the LEDS. There must be no
primary voltage when changing LEDS.
•When connecting the lamps, please ensure the polarity
matches! A polarity error may damage the LED module.
•The installation of a protection against any over voltage
by the customer compliant with standards DIN VDE
0100-443, DIN VDE 0100-534 and In 62305 is
recommended.
•Please observe the measures against electrostatic
discharge during all work on the spotlights, equipment
and LED.