USE AND CARE
Follow wiring instructions packed with range hood, and adhere to
all local and state codes, and the National Electrical Code.
WARNING: To reduce the risk of electric shock,
disconnect from power supply before servicing.

SERVICE PARTS

KEY NO. PART NO.
1
97014853 Damper Flap
2
99150415 Screw, #8B x ¼* (16 req.)
3
98009520 Duct Connector (2 req.)
4
97014784 Housing Assembly
5
97014728 Mounting Bracket (2 req.)
6
99150591 Mounting Screw, #10-12 x .625 (4 req.)
7
97006142 Wiring Harness
8
99150471 Ground Screw, #10-32 x ½* (2 req.)
9
98005512 Wiring Adapter Plate
10
99420470 Access Panel Nut (4 req.)
11
98009531 Movable Housing Panel
12
93150487 Screw, #10-24 x .375* (8 req.)
13
98005513 Outlet Box Cover
14
99400035 Strain Relief Bushing
15
97014788 Motor Bracket
16
99260477 Whiz Nut, ¼-20* (11 req.)
17
99200202 Screw, ¼-20 x ½* (5 req.)
18
97014785 Blower Scroll
19
99080490 Motor (HLB9)
99080491 Motor (HLB11)
20
93260447 Nut, Hex Flange 5/16-18* (5 req.)
21
98009516 Support Bracket
22
99020286 Blower Wheel
23
98009514 Inlet Ring
24
99150417 Screw, #8-18 x ¼* (5 req.)
25
98009513 Scroll Support Channel
+
97016794 Blower Assembly Complete
(Includes Key Nos. 15 thru 25)
+
97016795 Blower Assembly Complete
(Includes Key Nos. 15 thru 25)
26
98009532 Access Cover
27
99150472 Access Cover Screw (4 req.)
28
97016791 Hanger Kit
29
99610015 Transition, 8" x 12" to 10" Round, Male
30
99610028 Transition, 8" x 12" to 10" Round, Female
O rder replacement parts by PART NO. - not by KEY NO.
* Standard hardware - may be purchased locally.
+ Not shown assembled.
WARRANTY
Broan-NuTone warrants to the original consumer purchaser of its products that such products will be free from defects in materials or workmanship for a period of one year from the date of original purchase. THERE ARE NO
OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
During this one-year period, Broan-NuTone will, at its option, repair or replace, without charge, any product or part which is found to be defective under normal use and service.
THIS WARRANTY DOES NOT EXTEND TO FLUORESCENT LAMP STARTERS, TUBES, HALOGEN AND INCANDESCENT BULBS, FUSES, FILTERS, DUCTS, ROOF CAPS, WALL CAPS AND OTHER ACCESSORIES FOR DUCTING.
This warranty does not cover (a) normal maintenance and service or (b) any products or parts which have been subject to misuse, negligence, accident, improper maintenance or repair (other than by Broan-NuTone), faulty
installation or installation contrary to recommended installation instructions.
The duration of any implied warranty is limited to the one-year period as specified for the express warranty. Some states do not allow limitation on how long an implied warranty lasts, so the above limitation may not apply to you.
BROAN-NUTONE'S OBLIGATION TO REPAIR OR REPLACE, AT BROAN-NUTONE'S OPTION, SHALL BE THE PURCHASER'S SOLE AND EXCLUSIVE REMEDY UNDER THIS WARRANTY. BROAN-NUTONE SHALL NOT BE LIABLE
FOR INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES ARISING OUT OF OR IN CONNECTION WITH PRODUCT USE OR PERFORMANCE. Some states do not allow the exclusion or limitation of incidental or consequential
damages, so the above limitation or exclusion may not apply to you.
This warranty gives you specific legal rights, and you may also have other rights, which vary from state to state. This warranty supersedes all prior warranties.
To qualify for warranty service, you must (a) notify Broan-NuTone at the address or telephone number below, (b) give the model number and part identification and (c) describe the nature of any defect in the product or part. At
the time of requesting warranty service, you must present evidence of the original purchase date.
DESCRIPTION
(
HLB9
)
(
HLB11
)
BROAN-NUTONE ONE YEAR LIMITED WARRANTY
To clean blower assembly: Remove access panel, unplug blower
from housing, remove blower mounting nuts, and carefully remove
blower from housing. Use appropriate vacuum attachment or a soft
cloth and mild soap or detergent to clean blower discharge area and
wheel. DO NOT ALLOW WATER TO ENTER MOTOR. Make sure
blower assembly is completely dry before reinstalling.
Motor is permanently lubricated. Do not oil or disassemble motor.
29
1
2
3
7
2
8
16
10
9
14
13
6
16
15
17
21
19
17
20
27
Broan-NuTone LLC, 926 W. State Street, Hartford, Wisconsin 53027 www.broan.com 800-558-1711
Broan-NuTone Canada, Inc., 1140 Tristar Drive, Mississauga, Ontario L5T 1H9 www.broan.ca 877-896-1119
Page 4
30
4
28
5
12
3
2
11
22
18
25
BLOWER
16
ASSEMBLY
26
99043702E
23
24

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Hlb11

Table des Matières