9. Specifications
Bandwidth
Attenuation Ratio
Accuracy
Rise Time
Input Impedance
Input Voltage
- Differential Range
Input Voltage
- Common Mode Range
Input Voltage
- Absolute Max.
(Differential or Common)
Measurement Category
Output Voltage
- Swing
Output Voltage
- Offset (typical)
Output Voltage
- Noise (typical)
Source Impedance
(typical)
CMRR (typical)
Ambient Operating
Temperature
Ambient Storage
Temperature
Ambient Operating
Humidity
Ambient Storage
Humidity
Power Requirements
- Standard
Power Requirements
- Optional
Length of BNC Cable
Length of Input Leads
Weight
Dimensions (LxWxH)
TT-SI 9001
DC to 25MHz (-3dB)
1:10 / 1:100
±2%
14ns
4M
// 5,5pF each side to ground
1:10 ±70V (DC+peak AC) or 70Vrms
1:100 ±700V (DC+peak AC)
or 700Vrms
1:10 and 1:100
±700V (DC+peak AC) or 700Vrms
1:10 and 1:100
±1400V (DC+peak AC) or 1000Vrms
CAT III
±7V (into 50k
load)
<±5mV
0,7mVrms
50 (for using 1M input system
oscilloscope)
-86dB @50Hz, -66dB @20kHZ
-10°C to 40°C
-30° C to 70°C
25% to 85% RH
25% to 85% RH
4 x AA Cells
Power lead or Mains Adapter
(6VDC/60mA or regulated
9VDC/40mA)
95cm
45cm
400g (probe and PVC jacket)
170mm x 63mm x 21mm
TT-SI 9002
DC to 25MHz (-3dB)
1:20 / 1:200
±2%
14ns
4M
// 5,5pF each side to ground
1:20 ±140V (DC+peak AC) or 140Vrms
1:200 ±1400V (DC+peak AC)
or 1000Vrms
1:20 and 1:200
±1400V (DC+peak AC)
or 1000Vrms
1:20 and 1:200
±1400V (DC+peak AC)
or 1000Vrms
CAT III
±7V (into 50k
<±5mV
0,7mVrms
50 (for using 1M input system
oscilloscope)
-80dB @50Hz, -60dB @20kHz
-10°C to 40°C
-30° C to 70°C
25% to 85% RH
25% to 85% RH
4 x AA Cells
Power lead or Mains Adapter
(6VDC/60mA or regulated 9VDC/40mA)
95cm
45cm
400g (probe and PVC jacket)
170mm x 63mm x 21mm
14