5) Try to put 1 to 8 digit random false codes to the keypad. The keypad generates 5 beeps for each unsuccessful
code entry after the # button is pressed. The keypad locks during 30 seconds after 10 successive false codes are
entered. Normal operation will be resumed after the 30 seconds are expired.
Re-program the keypad for other operation modes
6) To access to programming mode, enter your Personal Master Code and validate via *.
3 2 8 9
7) Set relay output 1 in Start/Stop Mode with Accelerated Code.
4 2
#
8) Set keypad to activate Duress Output after 10 successive false codes.
7 1
#
9) To leave programming mode, press *.
*
Use the keypad with the re-programmed data
10) The relay output 1 has been programmed in Start/Stop mode with Accelerated Code. It is possible to activate the
output 1 with ONLY the First Two Digits of the user code 1. Deactivation of the output always require the
composition of the complete code.
e.g. Complete User Code 1 : 8321 Accelerated Code: 83
8 3
#
8 3 2 1
11) Try to put 1 to 8 digits false codes to the keypad. The keypad will activate the Duress Output after 10 successive
false codes are entered. To reset (deactivate) the Duress Output, you are required to enter the composition of the
User Code 1 and validate via #.
8. Specifications
* Operation Voltage
* Current Drain
* Duress Output
* Codes available
* Code Combinations
* Relay Outputs
* Dimensions
* Weight
The information in this manual is subject to change without prior notice.
HAA85
All manuals and user guides at all-guides.com
The keypad is in programming mode & ready to receive new
*
data.
Relay output 1 has been changed from Momentary to
Start/Stop with Accelerated code.
The keypad has been changed from locks 30 seconds to
activates Duress Output
The keypad is back to operation mode. The re-programmed
data have been stored.
Relay output 1 starts (activates)
Relay output 1 stops (deactivates)
#
12V DC (10-14VDC)
10 - 100mA
NPN transistor open collector switches to ground (-) when activated,
100mA/25V DC max
User 1 & 2, Super User, Master, Duress and Accelerated Codes
111111100
Output 1 -- 2 Amp, Output 2 -- 1 Amp, N.C. & N.O. dry contacts, 30V
DC max
117(H)mm X 74(W)mm X 48(D)mm
180g (net), 230g (gross) approx.
7