CHANGING REGULATORS
REGULATOR TYPES
Shown below are the two types of regulators used on Hestan outdoor appliances. Your conversion
EN
kit (AGBCK-NG or AGBCK-LP) comes with the appropriate regulator for the fuel type you are
converting to.
Remove your existing regulator by using a pipe wrench and other tools as required. Consult the GAS
CONNECTIONS section of your Hestan outdoor appliance for full instructions on installing the new
regulator, and providing accessible upstream gas shutoff valve (NG only). Use thread sealant on all
connections.
TESTING & ADJUSTMENT

LEAK TESTING

GENERAL
A complete gas tightness check must be performed of all gas-carrying components due to possible
movement during installation, or excessive pressure unknowingly being applied to parts of the unit.
BEFORE TESTING
BEFORE TESTING
Do not smoke while leak testing.
Never leak test with an open flame.
Make a soap solution of one part liquid detergent and one part water for leak testing purposes.
Apply the solution to the gas fittings by using a spray bottle or a brush.
For LP units, always check with a full LP cylinder.
4
©2020 Hestan Commercial Corporation
(continued)
2-STAGE LP
REGULATOR /
HOSE ASSEMBLY
(P/N 014309)
NAT GAS
REGULATOR
(P/N 006239)
ADAPTER, 3/8 FLARE
X 1/2 NPT FEMALE
(P/N 008053)