INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE.
THESE INSTRUCTIONS ARE TO BE USED IN CONJUNCTION WITH THOSE FOR THE GPV AND LHD50.
THIS INFORMATION SUPERSEDES THAT IN THE LHD50 INSTALLATION INSTRUCTIONS.
CONSUMER: RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Included in this kit:
W010-1777
Assembly, firestop spacer
W175-0309
Connector, reducer 5/8" to 4/7"
W500-0420
Plate, electrical box cover
W750-0218
Wire harness, unit
RP5
Restrictor Plate
The LHD50 uses 5" and 8" fl exible venting. When
installing the GPV for use with the LHD50, the 4" /7"
reducer (W175-0309) is required. The reducer must
be properly secured and sealed to unit using high
temperature sealant W573-0007 Mill Pac (not supplied)
before continuing with vent installation.
TERMINAL INSTALLATION
REFER TO GPV INSTALLATION INSTRUCTIONS
FIRESTOP VENTING INSTALLATION
The firestop assembly must be installed with the vent shield to the top.
Do not fill the cavity between the pipe and the framing with any type of material.
Terminals must not be recessed into a wall or siding more than the depth of the return flange of the
This application occurs when venting through an exterior wall. Having
determined the correct height for the air terminal location,
cut and frame a hole in the exterior wall as illustrated to
accommodate the fi restop assembly. Dry fi t the fi restop
assembly before proceeding to ensure the brackets on
the rear surface fi t to the inside surface of the horizontal
framing.
The length of the vent shield may be cut shorter for
combustible walls that are less than 8 1/2" thick but the
vent shield must extend the full depth of the combustible wall.
A. Apply a bead of caulking (not supplied) around the corner edge of
the inside surface of the fi restop assembly, fi t the fi restop assembly to the
hole and secure using the 4 screws W570-0026 (supplied in your manual
baggie).
B. Once the vent pipe is installed in its fi nal position, apply high
temperature sealant W573-0007 (not supplied) between the pipe and the fi restop.
PVAL50 POWER VENT ADAPTOR KIT
INSTALLATION INSTRUCTIONS
!
mounting plate.
WARNING
VENT
SHIELD
CAULKING
FIRESTOP
SPACER
3
11
/
"
8
7
9
/
"
8
DETERMINE
THE
CORRECT
HEIGHT
FINISHING
MATERIAL
1

Publicité

Table des Matières
loading

Sommaire des Matières pour Napoleon Fireplaces PVAL50

  • Page 1 PVAL50 POWER VENT ADAPTOR KIT INSTALLATION INSTRUCTIONS INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE. THESE INSTRUCTIONS ARE TO BE USED IN CONJUNCTION WITH THOSE FOR THE GPV AND LHD50. THIS INFORMATION SUPERSEDES THAT IN THE LHD50 INSTALLATION INSTRUCTIONS. CONSUMER: RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 WARNING DO NOT ALLOW THE INNER FLEX PIPE TO BUNCH UP ON HORIZONTAL OR VERTICAL RUNS AND ELBOWS. KEEP IT PULLED TIGHT. SPACERS ARE ATTACHED TO THE INNER FLEX PIPE AT PREDETERMINED INTERVALS TO MAINTAIN AN EVEN AIR GAP TO THE OUTER FLEX PIPE. THIS GAP IS REQUIRED FOR SAFE OPERATION. A SPACER IS REQUIRED AT THE START, MIDDLE AND END OF EACH ELBOW TO ENSURE THIS GAP IS MAINTAINED.
  • Page 3 VENT LENGTHS It is recommended that the gas power vent be used with a gas appliance that is equipped with Electronic Ignition. When installing the venting, these parameters supersede the Vent Installation Section in the appliance's Installation and Operating Instructions, as well as the following guidelines: Maximum horizontal vent run with no rise is 70 feet total.
  • Page 4 VENTURI ADJUSTMENT This appliance has an air shutter that has been factory set open according to the chart below: VENTURI BURNER Regardless of venturi orientation, closing the air shutter will cause a more yellow flame, but can lead to carboning. Opening the air shutter will cause a more blue flame, but can cause flame lifting from the burner ports.
  • Page 5: Installation De La Terminaison

    INSTRUCTIONS D’ INSTALLATION DE LA TERMINAISON MÉCANIQUE PVAL50 INSTALLATEUR : LAISSEZ CE MANUEL AVEC L’ APPAREIL. CES INSTRUCTIONS DOIVENT ÊTRE UTILISÉES CONJOINTEMENT AVEC CELLES DU GPV ET DU LHD50. CES INFORMATIONS REMPLACENT LES INSTRUCTIONS D’ INSTALLATION DU LHD50. PROPRIÉTAIRE : CONSERVEZ CE MANUEL POUR CONSULTATION ULTÉRIEURE.
  • Page 6: Ajout De Longueur D' Évent

    AVERTISSEMENT NE LAISSEZ PAS LA GAINE FLEXIBLE SE TASSER CONTRE LES COURSES HORIZONTALES OU VERTICALES ET LES COUDES. GARDEZ-LA TENDUE. DES ESPACEURS SONT FIXÉS À LA GAINE FLEXIBLE À INTERVALLES PRÉDÉTERMINÉS AFIN DE GARDER UN ESPACE VIDE AVEC LE CONDUIT EXTÉRIEUR. POUR QUE LE FONCTIONNEMENT SOIT SÉCURITAIRE, UN ESPACE VIDE EST REQUIS.
  • Page 7: Longueurs Des Conduits D' Évacuation

    LONGUEURS DES CONDUITS D’ ÉVACUATION Il est conseillé d’ utiliser la terminaison mécanique avec un appareil au gaz muni d’ un allumage électronique. Lors de l’ installation de l’ évacuation, les paramètres suivants remplaceront la section « Installation des évents » dans le manuel d’ instructions d’ installation et d’...
  • Page 8: Réglage Du Venturi

    RÉGLAGE DU VENTURI L’ ouverture du volet d’ air a été préréglée en usine selon le tableau ci-dessous : VENTURI Indépendamment de l’ orientation du venturi, plus le volet est fermé, plus la flamme est jaune et aura tendance à causer des dépôts de carbone.

Table des Matières