INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE.
THESE INSTRUCTIONS ARE TO BE USED IN CONJUNCTION WITH THOSE FOR THE GPV AND LHD50.
THIS INFORMATION SUPERSEDES THAT IN THE LHD50 INSTALLATION INSTRUCTIONS.
CONSUMER: RETAIN THESE INSTRUCTIONS FOR FUTURE REFERENCE.
Included in this kit:
W010-1777
Assembly, firestop spacer
W175-0309
Connector, reducer 5/8" to 4/7"
W500-0420
Plate, electrical box cover
W750-0218
Wire harness, unit
RP5
Restrictor Plate
The LHD50 uses 5" and 8" fl exible venting. When
installing the GPV for use with the LHD50, the 4" /7"
reducer (W175-0309) is required. The reducer must
be properly secured and sealed to unit using high
temperature sealant W573-0007 Mill Pac (not supplied)
before continuing with vent installation.
TERMINAL INSTALLATION
REFER TO GPV INSTALLATION INSTRUCTIONS
FIRESTOP VENTING INSTALLATION
The firestop assembly must be installed with the vent shield to the top.
Do not fill the cavity between the pipe and the framing with any type of material.
Terminals must not be recessed into a wall or siding more than the depth of the return flange of the
This application occurs when venting through an exterior wall. Having
determined the correct height for the air terminal location,
cut and frame a hole in the exterior wall as illustrated to
accommodate the fi restop assembly. Dry fi t the fi restop
assembly before proceeding to ensure the brackets on
the rear surface fi t to the inside surface of the horizontal
framing.
The length of the vent shield may be cut shorter for
combustible walls that are less than 8 1/2" thick but the
vent shield must extend the full depth of the combustible wall.
A. Apply a bead of caulking (not supplied) around the corner edge of
the inside surface of the fi restop assembly, fi t the fi restop assembly to the
hole and secure using the 4 screws W570-0026 (supplied in your manual
baggie).
B. Once the vent pipe is installed in its fi nal position, apply high
temperature sealant W573-0007 (not supplied) between the pipe and the fi restop.
PVAL50 POWER VENT ADAPTOR KIT
INSTALLATION INSTRUCTIONS
!
mounting plate.
WARNING
VENT
SHIELD
CAULKING
FIRESTOP
SPACER
3
11
/
"
8
7
9
/
"
8
DETERMINE
THE
CORRECT
HEIGHT
FINISHING
MATERIAL
1