INSTRUCTIONS MUST BE LEFT WITH THE OWNER FOR FUTURE REFERENCE AFTER INSTALLATION.
TOOL REQUIRED: 5/16" Hex Driver
1.
Remove the glass and screen frames, and the bottom
access panel from the side which is opposite the valve. The
glass and screen frame may be removed as a unit. It is not
necessary to separate the screen frame from the glass frame.
2.
Hold the blower assembly so that the magnets are on your
right side, and insert it into the unit through the opening to
the right of the junction box. See Figure 1.
3.
Attach the magnet-side of the blower assembly to the outer
wall of the fireplace, and center it inside the fireplace using
the two holes in the floor as a visual guide. See Figure 1.
4.
Set the rheostat control on the fireplace floor, with the
rheostat bracket situated as far to the right as possible.
See Figure 2.
35825-1-0220
INSTALLATION INSTRUCTIONS
FBB14 - 1 BLOWER
FOR USE ON: DVCP36(PP,SP)(3,7)-1 FIREPLACES
Figure 1
Figure 2
Empire Comfort Systems Inc. • Belleville, IL
5.
Snap the fan control disc into the forked prongs on the valve
bracket. See Figure 3.
6.
Unscrew the junction box from the locating tabs so that it
can be moved rearwards and plug in the blower cord. See
Figures 4 and 5.
7.
Re-attach the junction box to the locating tabs.
8.
Re-install the glass and screen frames, and the access panel.
Figure 3
Figure 4
Figure 5
Page 1