START UP PROCEDURE
The correct powering procedure of imago siren must initially to be done through the battery (6V. 1,2Ah
Dimensions: 98x50x22 mm - not included) and then giving power (13,8 Vdc typical) coming from the Control
Panel. It is fundamental to respect this order.
Once powered, the siren will give just a single flash from its main power LED and the buzzer will sound for a
second to verify the correct functioning of all parts ; moreover the red signaling LEDs will keep flashing (slow at
1 Hz) until the siren will remain open (tamper switches open). After closing the cover, the LEDs will flash faster (2
Hz) for 20 sec. If the siren has been powered also from the Control Panel, then the power LED will start to flash
(period 300/700ms) for 20 sec.; the siren will acquire the inputs stand-by condition and start its full functioning.
In case you still need to connect the power to the Control Panel, the siren will go in "low consumption mode"
waiting for the external power. If the siren will be opened again, the red LEDs will turn on, getting back to the
previous mode. Once the external power will be detected, the siren will let the power LED flash for 20 sec. and
after that, the siren will acquire the input stand-by condition and will start its full functioning. The imago siren will
sound and the power LED will be flashing (300ms ON / 700ms OFF) when:
1 External power is missing (wire cutting or voltage below 7,6Vdc).
2 The input [AL] goes in alarm (Universal version imago only).
3 The siren is being opened and JP1 is inserted (Tamper ON)(Universal version imago only).
4 The siren is being opened (KS-BUS version imago only).
In the case 1 e 2 the alarm condition will last until all power missing or alarm input active will last; in any case
for the maximum alarm time programmed by JP2, at the end of which even if the alarm conditions still exist,
only the power LED will keep flashing with setting 300ms ON / 1700ms OFF. To re-activate the acoustic signal it is
necessary to reestablish the alarm condition. In the case 3 the siren activates the alarm acoustic/flashing for the
programmed time, regardless from the restoring of the tamper condition.
PROGRAMMING - UNIVERSAL VERSION IMAGO ONLY
imago is available with the following functions, programmable through Jumpers:
1 Tamper signal on/off (JP1)
2 Buzzer timing set-up (3 or 10 minutes) (JP2)
3 Inputs configuration (JP3)
PROGRAMMABLE INPUTS - UNIVERSAL VERSION IMAGO ONLY
During the start-up, if JP3 is inserted, the siren will delete the settings of the inputs polarity, and will wait for its
removal. When the start-up procedure ends, the input status will be stored in the flash memory.
PROTECTION AND TAMPER WARNING
imago siren has two types of protection, one against the cover opening and another one against the removal
from the wall (two switches in series). The siren will check the status of these switches and will activate the
acoustic/optical warning when they are open. For imago universal version, when a tampering is detected the
siren will open two terminal to warn the Control Panel. The clamps relay [TAMP] reports the status of the tamper
protection switches regardless from the JP1 status. (Relay 100mA 24V max)