SET-UP
Before operating machine, please follow the instructions
listed below:
• Add Water
• Clean water must be used
• Use
included
hose
(hose not included)
• Fill up to "MAX" level only
• Plug the unit into a 115V/60Hz, single phase outlet
(Check outlet for correct polarity)
• Power indicator will light up
• Note: If the power cord is damaged, it must be
replaced by the manufacturer or a qualified electrician
to avoid hazards
MAINTENANCE
To ensure unit releases fresh and clean air, always
change the water when dirty and regularly clean the
cooling pad.
• Remove the filter by removing the screws
• Rinse the filter under running water to wash off dirt.
DO NOT use pressure washer.
• Pull out the cooling pad and wash both sides under
running water
• Note: Never use pressurized water
• Note: Never use liquid detergent. This may damage
the pad.
• Open the drainage valve to remove remaining water,
and then clean the water tank thoroughly with a soft
cloth to remove dirt
• Wash off dirt from the water sensor, water pump and
drainage valve
• Use mild soap and soft, clean cloth when cleaning the
housing and chassis
• Note: Do not use strong chemicals when cleaning unit
Control Panel
TROUBLESHOOTING
MALFUNCTION
Power indicator will not
light up.
Non-responsive
controls.
Drain valve leaks water.
Fan spouts wate.r
All manuals and user guides at all-guides.com
48 Inch
Evaporative Cooler
connector
on
left
side
Remote Control
Battery Not
Included
Uses CR2025
3V Battery
CAUSE
No power.
Breakers tripped.
Power frequency interference.
Environment interference.
Drain valve is loose.
Water pipe has fallen off.
CONTROL FUNCTIONS: Operate functions by pressing
button on control panel.
• Power "ON/OFF" switch
• Press "COOL" button to activate cooling function
• Water pump will circulate water into the cooling pad
for one minute, then the fan will activate
• Airflow Wind "SPEED" for desired airflow setting
(Low / Medium / High).
• "TIMER" button to set automatic timer. Dual Timer
• 24 Hour Timer can be set to start/stop in 1hour increments.
Water
Tank
Water Level
Gauge
Manifold
Water
Distributor
Motor
Support
Brace
Unit is unplugged.
Check reset breaker on GFCI plug.
Check breaker box in building.
Power off and on unit.
Remove or keep away from interference.
Tighten drain valve.
Check the water pipe.
2
User's Manual
Cooler
Housing
LCD
Panel
GFCI
Plug
Caster
Fan
Blade
Hose
Connector
Media Pads
SOLUTION