CONVERTING FROM TAMPER-PROOF TO KNOB-ADJUST MODE
1.
Disconnect the power to the device. Remove
the knurled cover from the housing assembly.
Remove the socket-head cap screw. See Figure 12,
page 6.
2.
Ensuring that the thermostat shaft remains
aligned with the cap screw hole, place the knob
onto the operating shaft and thread it into the cap
screw hole.
3.
When the operating shaft engages with the
thermostat shaft, with light finger pressure, gently
spring the thermostat away from the bracket
assembly, as shown in Figure 9, page 6 (DO
F.

TROUBLESHOOTING

Problem
Load will not turn on.
Load will not turn off.
Unit is not controlling to set point
G.

PREVENTATIVE MAINTENANCE

CAUTION. HAZARD OF ELECTRIC SHOCK. Turn
all power to system off. Use appropriate
disconnect lockouts and allow system/heater to
CAUTION
cool before performing any maintenance.
Mechanical Check
Check enclosure. Inside of enclosure must be clean,
dry, and free of foreign materials. Enclosure joints
are metal to metal. Do not use gasket material or
sealant in joints.
Check the tightness of all hardware. All nuts and bolts
must be tight.
NOT press down on the steel bracket). Rotate the
knob one more full revolution to assure a positive
engagement of the thermostat. Release the
thermostat.
4.
Upon release, the thermostat should spring back
into its original position. If the thermostat remains
sprung down, a slight twisting of the knob in both
directions should create a positive engagement.
The knob should be able to turn through the entire
temperature range but should not turn one full
revolution. If the knob turns completely around,
repeat Step 3 of this section.
1. Check:
Load
Wire connections
2. See wiring diagrams in Figure 4, page 4.
3. Faulty unit, contact factory.
1. Check for kinks in the capillary.
2. Faulty unit, contact factory.
1. Check that bulb is properly located in application.
2. Unit may be out of calibration, contact factory.
Electrical Check
Check all terminal connections and conductors. Tighten
loose connections. Conductors with damaged
insulation must be replaced.
Check all explosion-proof conduits. Replace damaged
conduits, unions, and plugs. Ensure 5 turns of
engagement on all threaded connections.
If enclosure is moisture resistant, check condition
of cover gasket. Contact factory, for component
replacement part.
Cause / Correction