Overview
For use with any 315 MHz SECURITY
having a purple "learn" button (refer to Step 4.)
The system uses biometric technology that enables an
authorized user to gain access by scanning their fi ngerprint.
The sensor strip on the unit makes a numeric template of the
fi ngerprint that is unique to that user. The unit's memory can
store up to ten fi ngerprints.
• The term "enroll" refers to scanning the fi ngerprint so the
device will recognize the user.
• The term "swipe" refers to the movement of the fi nger across
the sensor strip.
• The term "LED" stands for Light Emitting Diode. There are 6
LEDs located on the Fingerprint Keyless Entry.
When unit is on, it is programmed to shut off after a short period
of time. The unit's sensor strip is sensitive so it is important to
read the Tips for Success before attempting to use the
Fingerprint Keyless Entry.
Step 1 Install the Unit
1. Remove cover.
2. Fasten bottom screw to mounting surface. Allow 1/8" (3 mm)
to protrude above surface. Position unit on screw head and
adjust for snug fi t.
3. Fasten top screw. Replace cover.
1
3
®
garage door openers
2
Model 379LM-10 and 379LMC-10
Fingerprint Keyless Entry
To prevent possible SERIOUS INJURY or DEATH from a
moving gate or garage door:
• Install Keyless Entry Control within sight of the garage door,
out of reach of children at a minimum height of 5 feet
(1.5 m), and away from ALL moving parts of door.
• ALWAYS keep remote controls out of reach of children.
NEVER permit children to operate, or play with remote
control transmitters.
• Activate gate or door ONLY when it can be seen clearly, is
properly adjusted, and there are no obstructions to door
travel.
• ALWAYS keep gate or garage door in sight until completely
closed. NEVER permit anyone to cross path of moving gate or
door.
NOTICE: To comply with FCC and or Industry Canada (IC) rules, adjustment or modifi cations of
this receiver and/or transmitter are prohibited, except for changing the code setting or replacing
the battery. THERE ARE NO OTHER USER SERVICEABLE PARTS.
Tested to Comply with FCC Standards for Home or offi ce use. Operation is subject to the following
two conditions: (1) this device may not cause harmful interference, and (2) this device must
accept any interference received, including interference that may cause undesired operation.
Tips for Success
CORRECT
1. Make sure fi nger is clean and dry.
Place fi nger fl at above the sensor strip
with the top knuckle above the sensor.
2. Swipe fi nger straight down keeping
fi rm contact with the sensor. The swipe
should be a slow, constant speed.
SPECIAL NOTES: Use the same fi nger for
every swipe. It is important to swipe fi nger slowly and fi rmly as
this is the reason most swipes fail.
Start swipe with
the top knuckle
above the
sensor strip.
Sensor Strip
INCORRECT
• Do not bend fi nger during swipe as this will only scan the tip of
your fi nger.
• Swipe fi nger straight down, not at an angle.
• Swipe fl at, not tilted or rolled to one side.
1
Swipe finger straight down
keeping firm contact with
the sensor.
Sensor Strip
The scan
should end
at the tip of
finger.

Publicité

Table des Matières
loading

Sommaire des Matières pour Chamberlain LiftMaster PROFESSIONAL 379LM-10

  • Page 1 Model 379LM-10 and 379LMC-10 Fingerprint Keyless Entry Overview To prevent possible SERIOUS INJURY or DEATH from a For use with any 315 MHz SECURITY ® garage door openers moving gate or garage door: having a purple "learn" button (refer to Step 4.) •...
  • Page 2 Reference Step 3 Enroll Additional Users NOTE: The device can store up to ten fi ngerprints at a time. An enrolled user must swipe fi nger fi rst to enroll new user. Cover 1. Open cover and wait until Ready LED is lit.
  • Page 3 Step 4 Program to Opener Step 5 Operation 1. Open cover and wait until Ready LED is lit. ENROLL SEND ENROLL PASS FAIL READY RETRY 2. Swipe fi nger slowly and fi rmly down the sensor strip. NOTE: The unit must have an enrolled user before it can be programmed to the opener.
  • Page 4 FOR SERVICE DIAL OUR TOLL FREE NUMBER: — Ensure that suffi cient pressure is being applied to sensor 1-800-528-9131 strip (do not press too hard). — Ensure that the sensor and fi nger are not wet. © 2008, The Chamberlain Group, Inc. 114A3597 All Rights Reserved...
  • Page 5: Caractéristiques

    Modèle 379LM-10 et 379LMC-10 Système d’Ouverture Sans Clé à Empreintes Digitales AVERTISSEMENT AVERTISSEMENT Caractéristiques Afi n d’éliminer les risques de BLESSURES GRAVES ou de MORT Pour utilisation avec les ouvre-portes de Security:® 315 MHz découlant de l’actionnement d’une clôture ou d’une porte de garage : possédant un bouton «...
  • Page 6: Étape 3 Inscription D'utilisateur(S) Supplémentaire(S)

    Referencía Étape 3 Inscription d’utilisateur(s) supplémentaire(s) REMARQUE : L’appareil peut stocker jusqu’à quatre empreintes Couvercle digitales à la fois. Un utilisateur inscrit doit faire glisser son doigt en premier pour pouvoir inscrire un nouvel utilisateur. Bouton Resend (Renvoyer) : Lorsqu’il est appuyé, la porte 1.
  • Page 7: Étape 4 Programmation Au Dispositif D'ouverture

    Étape 4 Programmation au dispositif Étape 5 Fonctionnement d’ouverture 1. Ouvrez le couvercle et patientez jusqu’à ce que la LED Ready (Prêt) ENROLL s’allume. SEND ENROLL PASS FAIL READY RETRY 2. Faites glisser votre doigt lentement et fermement du haut vers le bas sur le capteur de bande.
  • Page 8: Dépannage

    — Vérifiez que l’emprunte digitale est inscrite. 1-800-528-9131 — Vérifiez qu’une pression suffisante est appliquée au capteur de bande (n’appuyez par trop fort). — Vérifiez que le capteur et le doigt ne sont pas mouillés. © 2008, The Chamberlain Group, Inc 114A3597 Tous droits réservés.

Ce manuel est également adapté pour:

Liftmaster professional 379lmc-10

Table des Matières