Index
Technical specifications .............................................................................................. 11
Safety notes ................................................................................................................ 11
General .......................................................................................................................... 12
Maintenance ................................................................................................................. 12
Panel description ......................................................................................................... 12
Voltage measurement DC ........................................................................................... 12
Voltage measurement AC ........................................................................................... 13
Current measurement DC ........................................................................................... 13
Current measurement AC ........................................................................................... 13
Resistance measurement ............................................................................................ 13
Capacitance measurement ......................................................................................... 14
Temperature measurement ........................................................................................ 14
Frequency measurement ........................................................................................... 14
Replace battery ............................................................................................................ 17
Replace fuse ................................................................................................................. 17
Equipment .................................................................................................................... 17
Assembling wrist-strap ................................................................................................ 10
Technical specifications
• Insulation: 600V CAT.III and 1000V CAT.II.
• Operation environment: from 0 to 40 °C <80% RH.
• Storage environment: from -10 to +50 °C
• Accuracy: see thecnical data page 15.
• Voltage to ground max.: 700V AC RMS - 1000V DC.
• Overload protection A: uA and mA with fuse 0,2A-250V - 10A not fuse.
• Sampling rate: approx. 3 time/sec.
• Display: 3
1
/
LCD 1999 auto polarity displaying.
2
• Measuring method: dual-integral A/D transfer.
• Overrange indication: MSD display "1" or "-1".
• Knob to change range and function.
• Low battery indication.
• Auto power off: the meter will be auto power off approximately ±10 min. -
Press POWER key twice can repower it.
• Power supply: one 9V battery type 6F22 (or equal).
• Dimension: 160x120x43 mm (without holster).
• Weight: 300 gr (400 gr including holster).
Safety symbols
Must refer to the manual.
Existing dangerous voltage.
Ground.
Dual insulation.
<80% RH.
11
Page
I
GB
F
D
E
P