EN
PROBLEM
Motor won't start
Motor turns without
pumping water
Flow rate insufficient
Tripped motor
oveload cutout
If these precautions aren't followed,
the pumps can be damaged and the
warranty will have no effect.
DECLARATION OF
CONFORMITY
We declare under our exclusive
responsibility, that the product
SELF-PRIMING JET PUMP with
code VIBAF750; VIBAF1100;
VIBAF1500, meets the following
standards or standardization
documents:
EN 60034, EN 60335,
EN 62233, EN 61000, EN 809,
EN ISO 12100, EN 60204,
EN ISO 13857 e EN ISO 13849,
according to the determinations of
the directives:
2014/30/EC - Electromagnetic
Compatibility Directive;
2014/35/EC - Low Voltage
Directive;
2006/42/CE - Machinery
Directive.
2000/14/CE - Sound power level
guaranteed
CAUSE
No power
Impeller stuck
Clogged filter
Excessive intake height
Air in intake
Clean filter
Intake height at limit
Filter partially clogged
Impeller blocked
Overheated motor
Impeller stuck
S. João de Ver,
14 th of April of 2014.
Central Lobão S. A.
Responsible for the Technical File
SOLUTION
Check connections and voltage values
See section on maintenance
Move pump closer to water outler level
Check intake pipe is airtight
Make sure foot valve is immersed by at
least 60 cm
Pump needs to be primed again
Check intake height
Clean foot valve and, if necessary, whole
intake pipe
Disassemble pump and carefully clean
pump body and impeller
Check voltage and ventilation
Release impeller (see section on mainte-
nance)
WARRANTY TERMS
The warranty of this machine is two
years from the date of purchase.
You should, therefore, keep your
proof of purchase during this period
of time. The warranty covers any
manufacturing defect in material
or operating, as well as parts and
work needed for their recovery.
Excluded from the warranty
the misuse of the product, any
repairs carried out by unauthorized
persons (outside the service center
of the brand VITO) as well as any
damage caused by the use of it.
11