Technical data
Poor cooling, interior temperature increases
Fault
Compressor runs for a
long time/continuously
Compressor runs
intermittently
Unusual noises
Fault
Loud humming
12
Technical data
Item number:
Voltage:
Capacity:
Average power consumption:
Cooling temperature range:
Relative humidity:
Constant inclination:
Dimensions (WxHxD) in mm:
Weight:
Test/certificates:
Versions, technical modifications and delivery options reserved.
The coolant circuit contains R134a.
34
Possible cause
Vaporiser is iced over
Ambient temperature too high
Insufficient ventilation and/or air sup-
ply
Condenser is dirty
Fan defective (if installed)
Battery capacity exhausted
Possible cause
A component of the refrigerant circuit
cannot move freely (touching the wall)
Foreign body jammed between the
cooling unit and the wall
Fan noise (if installed)
Remedy
Defrost the vaporiser
–
Move the freezer to
another location
Clean the condenser
Replace the fan
Charge the battery
Remedy
Bend the component
carefully away from the
obstruction
Remove the foreign body
–
CRF-0050E
12 V DC or 24 V DC
47 l
45 W
0 °C to max. -18° C
maximum 90%
max. 30°
448x527x543
25 kg
complies with ErP/EuP directive
CoolMatic CRF-50