INSTALLATION INSTRUCTIONS
TOUCH SCREEN VENTILATION CONTROLLER
*COMPATIBLE WITH SHR/VHR (HRV), SER (ERV) AND FLEX SERIES UNITS
CAUTION
FAILURE TO COMPLY WITH THE FOLLOWING CAN CAUSE ERRATIC OPERATION OF THE UNIT:
NEVER INSTALL MORE THAN ONE CENTRAL VENTILATION CONTROL PER UNIT.
KEEP CONTROL LOW VOLTAGE WIRING AT LEAST 1 FOOT (305MM) AWAY FROM MOTORS, LIGHTING BALLAST AND LIGHT DIMMING CIRCUIT.
DO NOT ROUTE CONTROL WIRING ALONGSIDE HOUSE POWER WIRING.
ENSURE THE WIRES ARE SECURELY CONNECTED TO THE UNIT AND WALL CONTROL.
BEST PRACTICES
FOR OPTIMAL OPERATION OF THE VENTILATION CONTROL, THE FOLLOWING BEST PRACTICES ARE RECOMMENDED DURING INSTALLATION:
AS A SAFETY PRECAUTION, DISCONNECT THE POWER TO THE HRV/ERV UNIT BEFORE INSTALLING THE VENTILATION CONTROL. ENSURE THAT
POWER IS RECONNECTED ONCE VENTILATION CONTROL HAS BEEN INSTALLED. FAILURE TO DISCONNECT POWER BEFORE INSTALLATION
COULD DAMAGE THE CONTROLLER.
THE LOCATION OF THE VENTILATION CONTROL COULD AFFECT THE OPTIMUM PERFORMANCE. THEREFORE, IT IS RECOMMENDED THAT THE
WALL CONTROL BE INSTALLED IN A CENTRAL LOCATION, AWAY FROM DIRECT SUNLIGHT AND OTHER SOURCES OF DIRECT HEAT OR COLD
SUCH AS OUTSIDE WALL OR ADJACENT TO WINDOWS.
DO NOT INSTALL VENTILATION CONTROLLER ON WALL WHERE CAVITY IS OPENED TO OTHER AREAS. EXAMPLE: FURNACE RETURN IN WALL
CAVITY. IF SO, SEAL THE BACK PLATE CENTER OPENING WITH TAPE.
INSTALLATION STEPS
1
3
DETACH FRONT MODULE FROM
BACK PLATE BY PRESSING THE
TAB (LOCATED AT THE BOTTOM
OF THE CONTROL CASING).
NOTE: BE SURE NOT TO EXERT
TOO MUCH PRESSURE ON THE
TAB.
INSERT
SIGNAL
WIRES
INTO THE TERMINAL BLOCK,
LOCATED ON THE BACKSIDE OF
THE FRONT MODULE. SECURE
THEM IN PLACE BY TIGHTENING
THE TERMINAL SCREWS USING
A SMALL 3.0 MM SLOT/FLAT
HEAD
SCREWDRIVER
(NOT
INCLUDED).
NOTE: THE TERMINALS ARE NOT
POLARITY SENSITIVE.
5
LEAVE OPERATING INSTRUCTIONS WITH HOME OWNER.
(2)
2
GUIDE
THE
SIGNAL
(2)
THROUGH
THE
OPENING OF THE BACK PLATE
AND MOUNT THIS PLATE TO
EITHER A STANDARD ELECTRICAL
DEVICE BOX OR DIRECTLY TO
THE WALL USING SCREWS. IF
REQUIRED, USE WALL ANCHORS
(NOT INCLUDED).
NOTE: BE SURE THE SCREWS
ARE SECURE BUT DO NOT OVER
TIGHTEN.
THIS MAY RESULT IN
DAMAGE TO THE BACK PLATE.
4
ATTACH
FRONT
MODULE
MOUNTED BACK PLATE, FIRST
BY HOOKING THE TOP OF THE
FRONT MODULE TO THE TOP
CLIPS OF THE BACK PLATE, THEN
BY PRESSING THE BOTTOM OF
THE FRONT MODULE UNTIL YOU
HEAR A 'CLICK'.
ENSURE THE
VENTILATION AND SYSTEM IS
OPERATING.
NOTE: BE CAREFUL NOT TO PINCH
OR TRAP SIGNAL WIRES WHEN
ATTACHING THE FRONT MODULE
TO THE BACK PLATE.
WIRES
CENTRAL
TO
ITEM #: 400608