CONTROL PANEL
The LCD displays symbols
: Dehumidify Mode
: Defrost Mode
: Draining
: Fan start up
: Humidity Setting
: Ambient Humidity
: Total Running Hours
: Ambient temperature
OPERATION
• Plug in electrical cord
This dehumidifier must be plugged into a grounded polarized
115 VAC/60Hz outlet rated at least 15 amps.
Plug in electrical cord, the screen will be in standby mode:
• Turn the Unit ON
Press the "ON/OFF" key to turn the unit on.
The factory setting is continuous mode. The screen will display:
If humidity setting is greater than ambient humidity, the unit will
stop working after started 1 minute.
• Turn the unit OFF
Press the "ON/OFF" key to turn the unit OFF. When the unit turns
OFF, The water pump will run for 40 seconds to drain the residual
condensate water in the dehumidifier. The screen will appear
draining cursor
LGR Dehumidifier Low-Grain Refrigerant
145 Pints Per Day Water Pump
IMPORTANT: To avoid water spillage. Do not move the dehumidifier for at least
three minutes after turning the power off. Before transporting, always remove
the external drain hose, drain it fully, and return it to the pocket provided on the
front of the unit.
• Humidity Setting
The factory setting is continuous mode, CO. The humidity
can be set in the following manner:
1. Press the function key
cursor flashes.
2. Press the regulate key
level. Adjust the humidity setting in increments of 5%.
Adjust the humidity setting between CO, 25% and 95%.
3. Wait 3 seconds after setting the desired humidity is
completed.
NOTES:
1. When the humidity setting is greater than ambient humidity,
the unit will stop and the screen will display:
2. When the Humidity setting is below 25% , the "CO" will be
displayed. The unit will enter the continuous dehumidify
mode, it will run continuously.
• Total running hours display and current job hours display
setting
1. Press the function key
cursor flashes.
2. Press the regulate key
3. It will flash for 3 seconds and the current Job hours will
be displayed.
For example as follows:
NOTE:
The "Total running hours" field displays continuously during
operation. This displays the total number of hours on the unit
and cannot be manually reset outside the factory.
• Centigrade/Fahrenheit setting
1. Press the function key
cursor flashes.
2. Press the regulate key
3. It will flash for 3 seconds and the temperature in
fahrenheit will be displayed.
4
Instruction Manual
until the humidity setting
to setting the desired humidity
NOTE:
The fan will run for 1 minute every
30 minutes to sense ambient
humidity. The unit will resume
operation when ambient humidity is
greater than humidity setting
until The total running hours the
to change to Current job hours.
until the ambient temperature
to switch to fahrenheit.