Télécharger Imprimer la page

Publicité

Liens rapides

Ref. 6760 - 6760/60A - 6770A - 6770B - 6770 - 170V
Notice d'installation / Installation instructions
6760
6770 (6770A + 6770B)
mm / inch
18 mm 3/4
O
44 mm 1 3/4
6760
46 mm 1 3/4
Lg : 2 M ( 78 3/4 " )
q
65 mm 2 1/2
q
65 mm 2 1/2
220V
75538
2021-09-08
6760/60A
170V
6760/60A
O
26 mm 1
1"
52 mm 2
Lg: 400 mm ( 15 3/4" )
1/2"
ø de perçage conseillé
recommended drilling ø
empfohlener abstand
Ø de perforación aconsejado
O
35 mm 1 3/8 "
110 mm 4 3/8 "
entraxe conseillé
recommended interval width
empfohlener abstand
distancia entre taladros aconsejado
75457
FR
Commande électronique seule, ouverture/fermeture et
contrôle de température
EN
Electronic control only, open / close and temperature control
Outillage (Non-fourni)
Tools (Not provided)
mm / inch
6770A
115 mm 4 1/2
46 mm 1 3/4
O
35 mm 1 3/8 "
220V
10/02/2021
75554
THG-PARIS.COM
L'installation doit être conforme
à la norme NFC 15-100
Installation must comply with NFC 15-100
6770
1/2"
q
65 mm 2 1/2
6770B
Lg: 400 mm ( 15 3/4" )
18 mm 3/4
1/2"
ø de perçage conseillé
recommended drilling ø
empfohlener abstand
Ø de perforación aconsejado
O
42 mm 1 5/8 "
11/02/2021
1

Publicité

loading

Sommaire des Matières pour THG PARIS 6760

  • Page 1 Ref. 6760 - 6760/60A - 6770A - 6770B - 6770 - 170V Notice d’installation / Installation instructions Commande électronique seule, ouverture/fermeture et 6760 6760/60A contrôle de température Electronic control only, open / close and temperature control Outillage (Non-fourni) Tools (Not provided)
  • Page 2 L’installation doit être conforme à la norme NFC 15-100 Ce produit fonctionne en 12V, le boitier avec transformateur doit être impérativement placé hors volumes 1 et 2 Installation must comply with NFC 15-100 This product operates on 12V, the box with transformer must be placed outside bathroom electrical zone 1 and 2 2021-09-08 THG-PARIS.COM...
  • Page 3 6760 Water 170V Hoses 6760/60A 6760 Electric wires 1 7 0 Alimentation hors volume / 6 0 Power Supply Outside bathroom electrical zone 1 and 2 COLD WATER WATER 6770A + 6770B = 6770 6770A 6770B Installation possible avec : Possible installation with : Ref.
  • Page 4 170V 6760/60A MAXI 40mm Exemple d’installation : Installation example : (170V) Hors volume Outside zones Water Hoses Electric wires 2021-09-08 THG-PARIS.COM...
  • Page 5 30mm max Exemple d’installation : 43GB *Non fourni Installation example : *Not provided (6770 + 43GB*) (6770A + 6770B) Hors volume Outside zones Water Hoses Electric wires 2021-09-08 THG-PARIS.COM...
  • Page 6 Branchements et installation du boîtier / Connections and box installation HOT COLD Fonctions / Functions Possibilité de COLD stopper même en cas de coupure de courant Can be stopped even in the event of a power cut COLD WATER MIXED WATER HOT WATER 2021-09-08 THG-PARIS.COM...
  • Page 7 50°C 38°C > 38°C Quick Access 1 Quick Access 2 Quick Access 3 Configurations usine Factory settings COLD WATER 30°C WATER 38°C WATER Pour changer la configuration How to change the settings Choisir température Choose temperature Violet (MAX 38°C) Purple Il est conseillé...
  • Page 8 Anomalies de fonctionnement / Operating anomalies Si la LED ne s’allume pas If light does Verifier not turn on Please check Vert Orange Green Orange Diagnostique Diagnostic Test d’eau chaude Mode nettoyage Hot water test (Attendre 45s ou appuyer 1x pour Eau chaude qui coule arrêter) Hot water flowing...

Ce manuel est également adapté pour:

6760/60a6770a6770b6770170v