Instructions for using the Flow Test Kit
1. Open loading valve by rotating counter-clockwise.
2. Start pump momentarily to ensure that oil flows freely through the hydraulic system, then
run pump at maximum speed. Do not change pump speed while turning the loading valve.
3. Slowly close the loading valve to develop the desired pressure. Run the machine until
normal operating temperature is reached i.e. typically +45°C...+60°C (+155°F...+140°F).
4. Open the loading valve to read the flow at minimum pressure.
5. Close loading valve slowly to increase pressure and note reduction of flow as the pressure
is increased to maximum pump pressure to determine pump condition.
Pump
Pump
Typical Tests
Pump Test
Cylinder
Tank
SDMKR
°F
°C
175
80
70
150
60
125
50
100
40
30
75
20
50
10
Overall System Test
Cylinder
Tank
SDMKR
°F
°C
175
80
150
70
60
125
50
100
40
30
75
20
50
10
Test Hose
Directional Valve
Relief
Valve
Test Hose
Directional Valve
Relief Valve
3