Télécharger Imprimer la page

Publicité

Les langues disponibles

Les langues disponibles

Liens rapides

IMPORTANT INSTRUCTIONS -
Models: B300, B500, B600
READ AND SAVE THESE INSTRUCTIONS
READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED.
PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH
INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE!
GENERAL SAFETY INFORMATION
electric shock and injury to person, including the following:
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Use this unit only in the manner intended by the manufacturer.If you
have questions, contact the manufacturer.
b) Before servicing or cleaning the unit, switch power off at
service panel and lock the service disconnecting means to
prevent power from being switched on accidentally. When the
service disconnecting means cannot be locked, securely fasten
a prominent warning device, such as a tag, to the service panel.
WARNING:
TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK
AND INJURY TO PERSON, OBSERVE THE FOLLOWING:
a) Installation work and electrical wiring must be done by qualified
person(s) in accordance with all applicable codes and standards,
including fire-related construction.
672016 Rev. C 4-10
OPERATING MANUAL
RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
When using electrical appliances, basic precautions
should always be followed to reduce the risk of fire,
SAVE THESE INSTRUCTIONS
b) Sufficient air is needed for proper combustion and exhausting
of gases through the flue (chimney) of fuel burning equipment to
prevent back drafting. Follow the heating equipment manufacturer's
guideline and safety standards such as those published by the
National Fire Protection Association (NFPA) and the American
Society for Heating, Refrigeration, and Air Conditioning Engineers
(ASHRAE), and the local code authorities.
CAUTION:
TO EXHAUST HAZARDOUS OR EXPLOSIVE MATERIALS AND VAPORS.
c) To avoid motor bearing damage and noisy and/or unbalanced
impellers, keep drywall spray, construction dust, etc. off power unit.
d) Read all instructions before installing or using exhaust fan.
e) Refer to the instructions included with the Range Hood Canopy for
additional safety information.
www.airkinglimited.com
Profesional Series
Blower
FOR GENERAL VENTILATING USE ONLY. DO NOT USE
1 of 8

Publicité

loading

Sommaire des Matières pour Ain King B300

  • Page 1 IMPORTANT INSTRUCTIONS - OPERATING MANUAL Profesional Series Models: B300, B500, B600 Blower READ AND SAVE THESE INSTRUCTIONS READ CAREFULLY BEFORE ATTEMPTING TO ASSEMBLE, INSTALL, OPERATE OR MAINTAIN THE PRODUCT DESCRIBED. PROTECT YOURSELF AND OTHERS BY OBSERVING ALL SAFETY INFORMATION. FAILURE TO COMPLY WITH INSTRUCTIONS COULD RESULT IN PERSONAL INJURY AND/OR PROPERTY DAMAGE! RETAIN INSTRUCTIONS FOR FUTURE REFERENCE.
  • Page 2 INSTALLATION INSTRUCTIONS Stud w/Hex Nuts CAUTION: MAKE SURE POWER IS SWITCHED OFF AT SERVICE PANEL BEFORE STARTING INSTALLATION. Screw Stud WARNING: THIS BLOWER IS INTENDED FOR USE ONLY IN AIR KING PROFESSIONAL SERIES RANGEHOOD CANOPIES MARKED SUITABLE FOR USE WITH THIS BLOWER. DO NOT INSTALL IN ANY OTHER APPLICATION.
  • Page 3 5. Plug both the 3 wire and 4 wire quick connect cords from the blower into the appropriate receptacles located on the inside front of the hood canopy. These cords will only fit into the receptacles one way (Figure 3). 6. Reinstall the rear bottom plate by fitting the back edge of the plate Fuse into the channel located on the back of the hood and reinstalling the two nuts and washers removed in Step 1 (Figure 5). Figure 6 Washer NOTE: If you need to replace the fuse, replace with a 1/4" x 1-1/4" Bussman MDA-3 or equivalent 3 amp, 250V ceramic, time delay fuse only. 2. Refer to the hood instruction manual to complete the installation, for maintenance, and before restoring power. Bottom Plate 3. The blower is covered under the range hood’s warranty. Figure 5 SECTION 4 Finishing the Installation 1. Install the included fuse into the electrical panel by turning the fuse cap counter clockwise and pulling out. Insert the included 1/4” x 1-1/4” time delay fuse in the holder and reinstall into the panel (Figure 6). 672016 Rev. C 4-10 www.airkinglimited.com 3 of 8...
  • Page 4 5 8 #8-32 Screw 5S1136103 6 8 Star Washers 5S1199250 7 1 Fuse 5S1136106 8 1 Capacitor 5S1136104 9 2 #6 Screws 5S1136129 10 1 Wire Harness (B300) 5S1136200 1 Wire Harness (B500) 5S1136201 672016 Rev. C 4-10 www.airkinglimited.com 4 of 8...
  • Page 5 INSTRUCTIONS IMPORTANTES – MODE D’EMPLOI Ventilateur de la série Modèles: B300, B500, B600 Professionnelle LIRE ET CONSERVER CES INSTRUCTIONS LIRE SOIGNEUSEMENT AVANT DE TENTER D’ASSEMBLER, INSTALLER, OPÉRER OU DE RÉPARER LE PRODUIT DÉCRIT. PROTÉGEZ VOUS-MÊME ET LES AUTRES EN OBSERVANT TOUTE L’INFORMATION DE SÉCURITÉ. FAILLIR À SE CONFORMER AUX INSTRUCTIONS PEUT RÉSULTER EN BLESSURE PERSONNELLE GRAVE ET/OU EN DOMMAGE À...
  • Page 6 INSTRUCTIONS D’INSTALLATION Montants avec écrous hexagonaux AVERTISSEMENT : VOUS ASSURER QUE L’ALIMENTATION EST COUPÉE AU PANNEAU DE SERVICE AVANT DE Montant COMMENCER L’INSTALLATION. de vis AVERTISSEMENT : CETTE SOUFFLANTE EST CONCUE UNIQUEMENT POUR UTILISATION AVEC LES COUVERCLES DE HOTTE DE CUISINIERE DES SERIES PROFESSIONNELLES DE AIR KING MARQUEES Trou en APPLICABLES POUR UTILISATION AVEC CETTE SOUFFLANTE.
  • Page 7 4. En utilisant 8 des vis #8-32 incluses, les rondelles plates et en étoile, montez le ventilateur en place et serrez toutes les vis. Confirmez que le ventilateur est solidement en place et qu’il n’y a aucun entrefer autour du joint du ventilateur. Capuchon 5. Brancher les cordons à connecteurs rapides à 3 fils et 4 fils de la Fusible soufflante dans les réceptacles appropriés situés sur l’intérieur de l’avant du couvert de la hotte. Ces cordons ne s’ajusteront que d’une seule manière dans les réceptacles (Figure 3). 6. Réinstaller la plaque du bas à l’arrière en ajustant le rebord arrière Figure 6 de la plaque dans le canal situé sur l’arrière de la hotte et en réin- stallant les deux écrous et rondelles enlevées à l’Etape 1 (Figure 5). REMARQUE : Si vous aviez besoin de remplacer le fusible, le remplacer avec un fusible Bussman MDA-3 de 0,6 x 3,2 cm ou un fusible Écrou équivalent à 3 ampères, 250V, céramique, à retardement uniquement. Rondelle 2. Référez-vous au manuel d’instruction de la hotte pour compléter l’installation, pour l’entretien et avant de remettre l’alimentation. 3. La soufflante est couverte par la garantie de la hotte de cuisinière. Plaque du bas Figure 5 SECTION 4 Terminer l’installation 1. Installer le fusible compris dans le panneau électrique en tournant le capuchon du fusible en sens horaire et en tirant. Insérer le fusible à retardement de 0,6 x 3,2 cm dans le porte fusible et...
  • Page 8 5 8 Vis de #8-32 5S1136103 6 8 Rondelle en étoile 5S1199250 7 1 Fusible 5S1136106 8 1 Condensateur 5S1136104 9 2 Vis de #6 5S1136129 10 1 Harnais de câbles (B300) 5S1136200 1 Harnais de câbles (B500) 5S1136201 672016 Rev. C 4-10 www.airkinglimited.com 8 of 8...

Ce manuel est également adapté pour:

B500B600