Setting curtain positions (6300 and 6600)
Determining end positions
End positions of the curtain are determined by the position of the endstops 6002. The end
positions can be changed by moving and securing the end stops to an alternative location on
the profile. Using hexagonal Allen key size No. 2.
Changing button functions for opening and closing
First remove all plugs from the motor-unit on a system already connected. Place an RF
receiver in port 2 (black) on the under side of the motor-unit and then insert the round 24V
!
supply plug.
When not being operated the motor-unit will automatically exit the programming mode after1
minute: the LED will go out, return to step 1.
For several linked systems:
!
Remember that changing the "open" and "close" positions will have consequences for any
central control of linked
Control
6002
STEP 1
Using the transmitter, keep the stop button pressed: a green led will start
flashing in the bottom of the motor unit, release the button only when the
LED flashes red. (after approx.8 seconds). The system overlap carrier will
move briefly in both directions.
STEP 2
Briefly press the desired button for closing the curtains.
The system will close to confirm the new setting and the LED goes out
Functions of OPEN and CLOSE buttons:
- Keeping 'open' or 'close' button pressed for more than 1 second: the
system will run until the button is released.
- briefly press and release either button, less than 1 second: the system
will run until an end-position is reached or until the button is again
briefly pressed and released.
Functions of STOP button :
- pressed briefly and released: the system stops if running.
- keep the button pressed longer: the motor unit enters programming
mode.