Fixing
The appliance must be installed
supporting surface.
Any deformities caused by improper fixing could affect the
features and operation of the hob.
The thickness of the supporting surface
the length of the screws for the fixing
account when choosing
hooks:
• 30 mm thick: 23 mm screws
• 40 mm thick: 13 mm screws
Fix the hob as follows:
1. Use short flat-bottomed screws to fix the 4 alignment
springs in the holes provided at the central point of each
side of the hob.
2. Place the hob in the cavity, make sure it is in a central
position and push down on the whole perimeter until the hob
is stuck to the supporting surface.
3. For hobs with raised sides: After inserting the hob into its
cavity, insert the 4 fixing hooks (each has its own pin) into
the lower edges of the hob, using the long pointed screws to
fix them in place, until the glass is stuck to the supporting
surface.
!
The screws for the alignment springs must remain
accessible.
!
In order to adhere to safety standards, the appliance must
not come into contact with electrical parts once it has been
installed.
!
All parts which ensure the safe operation of the appliance
must not be removable without the aid of a tool.
Electrical connection
!
The electrical connection for the hob and for any built-in
oven must be carried out separately, both for safety
purposes and to make extracting the oven easier.
Single-phase connection
The hob is equipped with a pre-connected electricity supply
cable, which is designed for single-phase connection.
Connect the wires in accordance with the instructions given
in the following table and diagrams:
Voltage and
Electrical cable
mains frequency
220-240V 1+N ~
50 Hz
Other types of connection
If the mains supply corresponds with one of the following:
Voltage and mains frequency
• 400V - 2+N ~ 50 Hz
on a perfectly level
should be taken into
Wire connection
: yellow/green
N
: the two blue wires together
L
: brown and black together
• 220-240V 3 ~ 50 Hz
• 400V 3 - N ~ 50 Hz
• 400V - 2+2N ~ 50 Hz
Separate the wires and connect them in accordance with
the instructions given in the following table and diagrams:
Voltage and
Electrical cable
mains frequency
400V - 2+N ~
50 Hz
220-240V 3 ~
50 Hz
400V 3-N ~
50 Hz
400V - 2+2N ~
50 Hz
Connecting the electricity supply cable to the mains
If the appliance is being connected directly to the electricity
mains an omnipolar switch must be installed with a
minimum opening of 3 mm between contacts.
!
The installer must ensure that the correct electrical
connection has been made and that it is fully compliant with
safety regulations.
Before connecting the appliance to the power supply, make
sure that:
• The appliance is earthed and the plug is compliant with
the law.
• The socket can withstand the maximum power of the
appliance, which is indicated on the data plate located on
the appliance itself.
• The voltage falls within the range of values indicated on
the data plate.
• The socket is compatible with the plug of the appliance. If
the socket is incompatible with the plug, ask an
authorised technician to replace it. Do not use extension
cords or multiple sockets.
!
Once the appliance has been installed, the power supply
cable and the electrical socket must be easily accessible.
!
The cable must not be bent or compressed.
!
The cable must be checked regularly and replaced by
authorised technicians only.
!
The manufacturer declines any liability should these safety
measures not be observed.
! Do not remove or replace the power supply cable for any
reason. Its removal or replacement will void the warranty and
the CE marking. INDESIT does not assume liability for
accidents or damage arising from replacement/removal of
the original power supply cable. Replacement can only be
accepted when carried out by personnel authorised by
INDESIT and using an original spare part.
GB
Wire connection
: yellow/green;
N: the two blue wires
together
L1: black
L2: brown
: yellow/green;
N1: blue
N2: blue
L1: black
L2: brown
27