Safety notices
• Do not switch on the humidifier if it does not contain water.
• Transformer, power cable, switch and the connectors have to be checked regularly for
damages. In case of damage the humidifier has to be taken from operation immediate-
ly or rather may not be put into operation.
• The cable between the transformer and the device should always be installed with
a U-bend (cable hanging down) so that no water drops run along the cable into the
transformer.
• Before commissioning a device, it must generally be checked whether this device is
basically suitable for the application for which it is to be used!
• In case of doubt consultation of experts or the manufacturers of the employed devices
is required!
• Use in terrariums or outdoors is not permitted.
• Disconnect the humidifier from the power supply when removing the water tank or
moving the unit.
• The device may only be used with the transformer supplied by the manufacturer.
• Keep the device as far away from electromagnetic fields as possible.
• Do not disassemble the device or make any technical changes.
• Do not operate the device in locations with high humidity.
Trouble Shooting
Fault
No fog - switch at the front of the unit
does not light up
No fog - switch at the front of the unit
lights red
No fog- switch at the front of unit lights
green
Weak fog performance
Unusual noises
List of offered replacement articles
Head with membrane
Cartridge holder including cartridge
Hose
Technical Specifications
Humidification capacity:
Water tank capacity:
Input voltage:
Supply voltage:
Power consumption:
Measurements:
Warranty
The implied warranty applies. The warranty does not cover the membrane. The warranty
is void if used improperly or if the device has been tampered with!
Fault Analysis
No power supply
Unit has power but not switched on
Empty water Container
Water drops on the membrane
Cartridge has no contact to the membrane
Cartridge has frayed too much and therefore has
no contact
Dirty or stale water
Cartridge has only bad contact with the
membrane
Dirty, limy or damaged membrane
Very little water in the container
Water drops on the membrane
Cartridge has only bad contact with the
membrane
Dirty, limy or damaged membrane
SN-3
SN-4
SFM-2
Solution
Check the power supply - Is the transformer
connected to a working socket? Are both plugs
connected correctly? If the unit still does not
work, contact your dealer.
1x Press the start button, the switch lights green
and the device works.
Fill up with water
Remove the nozzle and suck off the drop with a
tip of an absorbent material or simply wait a few
seconds until the water drop is atomized.
Remove the cartridge holder and place the
cartridge correctly, if necessary push it slightly
upwards so that it stands out a little longer.
Replace cartridge with a new one
Clean water tank and replace water
Check positioning and change cartridge if
necessary
Replace membrane. Please read the operating
instructions!
Fill up with water
Remove the nozzle and suck off the drop with a
tip of an absorbent material.
Check seat and replace cartridge if necessary
Replace membrane. Please read the operating
instructions!
62373
62374
62308
30 ml/h
max. 360 ml
AC 100 – 240V 50/60Hz
DC 5V
1,5 W +- 0,5W
ø ca. 90x205 mm + Hose
3