Sommaire des Matières pour Dustbane Power Clean 900 XT
Page 1
Parts & Operations Manual Manuel de pièces et d’opérations Power Clean 900 XT Carpet Extractor/ Extracteur à tapis Code : 19384 Serial Number: Date of Purchase: Numéro de série : _____________________ Date d’achat : ________________________ More info/Plus d’info : www.dustbane.ca 2017-03...
Page 3
This unit is intended for commercial use. This manual, included with every Dustbane Power Clean 900 XT Self-Contained Carpet Extractor, provides the necessary operating and preventive maintenance instructions. Operators must read and understand this manual before operating or servicing this machine.
Page 4
Electrical The Power Clean 900 XT is designed to operate on a standard 15 Amp. 115 volt, 60 hz, AC circuit. Voltages below 105 volts AC or above 125 volts AC could cause serious damage to the motor.
Page 5
Assembly Connect the handle assembly to the machine. 1. Unpack machine. 2. Use phillips screwdriver to unscrew 3. Insert handle assembly in between 4 screws and remove cover. bushings. Insert the shoulder bolt through the bushing and screw into the handle assembly using supplied wrench.
Page 6
Machine Overview Front Vacuum Connection A - Handle K - Vacuum Motor Intake Cover B - Recovery Dome Lid L - Vacuum Connection Tube C - Recovery Tank M - Recovery Inlet D - Solution Tank N - Handle E - Solution Tank Fill Port P - Vacuum Float Shut-Off F - Faucet Fill Hose Q - Recovery Window Extension Hose...
Page 7
Handle Assembly The 900 XT Handle Assembly (D) is not assembled on the machine when shipped. Follow the instruction on the previous page to connect the handle assembly to the machine. A - Handle Adjustment Knob B - Shoulder Bolt C - Cover D - Handle Assembly E - Screw...
Page 8
Momentary Handle (A) When handle is pushed forward the spray jets shut off. Brush Switch (B) ON\OFF switch for brush. Flip switch up to (I) position to turn on the brush motor. Flip switch to (o) position to shut off brush motor.
Page 9
Solution Level Indicator The solution Tank Drain Hose also serves as a water level indicator for the solution tank. The amount of water remaining in the solution tank can be seen through the clear drain hose. Brush Removal • Use a 4mm or 5/32 Hex Tool to remove the flat-head screw on the underside of the right side of the brush housing.
Page 10
Removable Recovery tank To remove tank: Unclip dump hose from solution tank. Pull recovery tank straight up. To replace tank: Feed dump hose through opening in solution tank. Lower tank into place. Recovery vacuum inlet will rest on vacuum connection tube (See page 6, items L & M) Clip dump hose to solution tank.
Page 11
Maintenance User Maintenance Instructions All service and repairs should be performed by a qualified service representative or electrician. No user serviceable components are employed in the electrical assembly. No lubrication of the motor is required. BEFORE CLEANING OR MAINTAINING THE MACHINE, UNPLUG THE ELECTRICAL CORD.
Page 12
Cord Storage The 900 XT is supplied with a detachable cord for ease of storage. • Regularly inspect cord for signs of damage. If cord is damaged replace immediately. • Do not use with damaged cord or plug. If appliance is not working as it should, has been dropped, damaged, left outdoors, or dropped into water, return to service center.
Page 13
troubleshooting Caution! Unplug power cord before servicing machine components. PROBLEM Machine does not function CAUSE SOLUTION Power cord may be diconnected at the twist lock or wall outlet. Check connections and reconnect if necessary. Wall outlet breaker may have tripped. Reset breaker.
Page 14
The obligation of Dustbane Products Limited under this Warranty shall be limited to repairing or replacing, at its option, any part or parts of Dustbane Equipment which shall have been returned to a Dustbane authorised repair depot, and which, upon examination, shall disclose to the satisfaction of Dustbane Products Limited to have been defective, whereupon any required repair or replacement shall be made by such Dustbane authorised repair depot.
Page 15
été réparés ou modifi és par toute personne ou personne ailleurs qu’à un centre de service de réparation autorisé Dustbane de telle façon à ce que, dans l’avis de « Les Produits Dustbane Limitée », son rendement et sa fi abilité en soient défavorablement altérés;...
Page 17
Main Assembly Part no. Description Quantity Part no. Description Quantity ASY-SOLUTION TANK SCR-HH M6-1.0 X 16 ZP 4-173010 30 4-1103807 115VAC BLUE CLASS 8.8 NUT-NYLOC M5 X 0.8 ZD 4-173020 RECOVERY TANK ASSY 31 4-12040036 CLASS 6 HANDLE BRACKET 4-173035 BUSH-FLG LH&RH-HANDLE, WELDMENT 4-553130054...
Page 18
Parts - Pièces Solution tank Assembly Front View...
Page 19
Solution tank Assembly Rear View Part no. Description Quantity Part no. Description Quantity 37 4-712764 WSR #10 SS 4-121082 FAUCET FILL HOSE ASSY 38 4-712772 WSR-FLAT .344 X .75 X .06 SS 4-130032 WHEEL RETAINER CAP VAC MOTOR ASY, 115V (115V 4-172018 SOLUTION TANK LID ASSY 40 4-740089...
Page 23
Recovery tank Assembly Part no. Description Quantity 4-173175 RECOVERY DOME LID 4-173177 GASKET, LID, RT 4-173178 GASKET, LID, LFT 4-173186 FILTER, DOME LID 4-173187 CABLE 12.0 4-712516 SCR-BHCS #8-32 X .62 SS 4-712764 WSR #10 SS 4-762410 BUSHING, .2 X .31 X .265 ALUM...
Page 38
Part no. Description 4-748602 SWITCH, BRUSH MOTOR 4-748602 SWITCH, VACUUM MOTOR 4-748603 SWITCH, SPRAY & AUXILARY 4-748611-1 SWITCH, MICRO MOMENTARY PUMP 4-748695 CIRCUIT BREAKER, 1.5A BRUSH MOTOR 4-748620 CIRCUIT BREAKER, 12A VACUUM MOTOR 4-748695 CIRCUIT BREAKER, 1.5A PUMP/SOLENOID & AUXILIARY 4-831238-2 MOTOR, BRUSH 4-740089-1...
Page 39
Conservez ces instructions. Lisez et suivez tous les avertissements et mises en garde avant d’utiliser cette machine. Cette unité est conçue pour un usage commercial. Ce manuel, qui est inclus avec tous les extracteur à tapis autonome Power Clean 900 XT, fournit les instructions d’opérations et de maintenance préventive nécessaire.
Page 40
Électrique Le Power Clean 900 XT est conçu pour fonctionner sur un ampli standard de 15 ampères. 115 volts, 60 Hz, circuit alternatif. Des tensions inférieures à 105 volts AC ou supérieures à 125 volts AC pourraient causer des dommages graves au moteur.
Page 41
- si elle ne convient pas à la prise de courant, installez une prise appropriée par un électricien qualifié. Le Power Clean 900 XT est destinée à être utilisé sur un circuit nominal de 115 volts et possède une fiche de mise à la terre Fiche de mise à...
Page 42
Vue d’ensemble de la machine Devant Raccord de l’aspirateur A - Poignée K - Couvercle du moteur de l’aspirateur B - Couvercle de récupération en dôme L - Tube de raccordement de l’aspirateur C - Réservoir de récupération M - Entrée de récupération D - Réservoir de solution N - Poignée E - Port de remplissage du réservoir de solution...
Page 43
Assemblage de la poignée L’assemblage de la poignée de 900 XT (D) n’est pas monté sur la machine lors de son expédition. Suivez les instructions sur la page 41 pour connecter l’assemblage de la poignée à la machine. A - Bouton de réglage D - Assemblage de la poigné...
Page 44
Poignée momentanée (A) Lorsque la poignée est poussée vers l’avant, les jets de pulvérisation sont fermés. Interrupteur de la brosse (B) L’interrupteur marche / arrêt pour la brosse. Déplacer l’interrupteur à la position (I) pour allumer la moteur de la brosse. Déplacer l’interrupteur à...
Page 45
Indicateur de niveau de solution Le boyau du réservoir de solution sert également d’un indicateur de niveau pour le réservoir de solution. La quantité d’eau dans le réservoir est visible à travers le boyau transparent. Enlever les brosses • Utilisez un outil hexagonal de 4 mm ou 5/32 pour retirer la vis à...
Page 46
Réservoir de récupération amovible Pour enlever le réservoir : Retirer le tuyau de vidange du réservoir de solution. Tirez le réservoir de récupération vers le haut. Pour remplacer le réservoir : Introduire le tuyau de vidange à travers l’ouverture dans le réservoir de solution. Remettre le réservoir en place.
Page 47
Entretien Instructions d’entretien de l’utilisateur Tous les services et réparations doivent être effectués par un technicien qualifié. Aucun composant réparable par l’utilisateur n’est utilisé dans l’ensemble électrique. Aucune lubrification du moteur n’est requise. AVANT DE NETTOYER OU DE MAINTENIR LA MACHINE, DÉBRANCHEZ LE CORDON ÉLECTRIQUE. Protéger le matériel du gel.
Page 48
Entreposage de cordon Le 900 XT est fourni avec un cordon détachable pour faciliter le rangement. • Inspectez régulièrement le cordon pour détecter tout signe de dommage. Si le cordon est endommagé, remplacez-le immédiatement. • Ne pas utiliser si le cordon ou la fiche est endommagé. Si l’appareil ne fonctionne pas comme s’il devrait, il a été échappé, endommagé, laissé...
Page 49
Guide de dépannage Mise en garde! Débrancher le cordon d’alimentation avant d’entretenir les composants de la machine. PROBLèME La machine ne fonctionne pas CAUSE SOLUTION Le cordon d’alimentation peut être débranché à la prise Vérifiez les connexions et rebranchez-les si nécessaire. de courant ou à...
Page 50
PROBLèME Le moteur de l’aspirateur ne démarre pas CAUSE SOLUTION Le disjoncteur a peut-être déclenché. Réinitialiser le disjoncteur. Brosse à moteur peut être usés. Contacter un technicien qualifié.