Wiring:
Important! Disable power before wiring up the microbar.
The wiring for the permanent mount microbar is as shown in Figure 6. All wiring
should be a minimum of 18AWG. The positive line must have a 5 amp fuse, as
shown. A switch may be used to control the on/off function.
5545 SINGLE
COLOR SERIES
(USER SUPPLIED)
FUSE (5A)
(USER SUPPLIED)
5550 SINGLE
COLOR SERIES
FUSE (5A)
(USER SUPPLIED)
(USER SUPPLIED)
5550 DUAL
COLOR SERIES
FUSE (5A)
(USER SUPPLIED)
(USER SUPPLIED)
FIGURE 6
1.5"
FIGURE 5
RED, POSITIVE
SWITCH
BLUE: FLASH PATTERN SELECT
(ISOLATE WHEN NOT IN USE)
BLACK
GROUND
RED, POSITIVE
COLOR 1
SWITCH
WHITE, POSITIVE
(USER SUPPLIED)
COLOR 2
SWITCH
BLUE FLASH PATTERN SELECT
(ISOLATE WHEN NOT IN USE)
BLACK
GROUND
YELLOW SYNC
(ISOLATE WHEN NOT
IN USE)
RED, POSITIVE
COLOR 1
SWITCH
WHITE, POSITIVE
(USER SUPPLIED)
COLOR 2
SWITCH
BLUE FLASH PATTERN SELECT
(ISOLATE WHEN NOT IN USE)
BLACK
GROUND
YELLOW SYNC
(ISOLATE WHEN NOT
IN USE)
Flash Pattern Selection:
For permanent mount microbars, flash patterns are selected by powering
the unit on and tapping the blue wire to the black wire to the black ground
wire for less than a second. Holding the blue wire to the black wire for 2-3
seconds will go to the previous pattern and holding the blue wire to the
black wire for 5 seconds will go to Steady Burn. In dual color microbars,
each of the three flash pattern options must be set individually.
SYCHRONIZATION:
The permanent mount microbars sync with compatible ECCO
products via the yellow wire:
1. Determine the desired style of flash pattern for each unit and set each
unit individually (without the yellow wires connected together) to avoid
confusion. It is also strongly recommended that the same style of flash
pattern be used on all units to produce the most effective warning
pattern. (NOTE: Phases A and B for each style of flash pattern in the
table denote the relative timing between units connected in a
synchronizing installation. To operate simultaneously, each unit must
be set to the same phase (A + A or B + B); to operate alternately, units
must be set to have the opposite phase (A + B or B + A)).
2. Connect the yellow sync wires together and check that the units are
flashing in a synchronized manner as expected. If a pattern on one
unit appears incorrect, the blue pattern select wire can be used to
cycle forward or backward on that individual unit until the correct
pattern is selected. Note: This will only change the pattern in the one
unit and will not affect the other units connected to the yellow sync
wire.
3. If the yellow wire is unused, leave unconnected and insulated.
Page 3 of 7