3-1. Specifications

Rated
Voltage
Welding
Welding
Range
Output
300 A @
32 Volts DC,
10 – 35
60% Duty Cycle
*While idling

3-2. Duty Cycle And Overheating

Overheating
SECTION 3 – INSTALLATION
Maximum
Amperage
Open-Circuit
Open-Circuit
Range
Voltage DC
5 – 400
70
60% Duty Cycle
6 Minutes Welding
0
Minutes
Amperes Input at Rated
IP
Load Output 50/60 Hz
Rating
380 V
21.0
23
(0.*)
4 Minutes Resting
15
OR
Reduce Duty Cycle
440 V
KVA
19.0
12.4
(0.*)
(0.09*)
(0.04*)
Duty Cycle is percentage of 10 min-
utes that unit can weld at rated load
without overheating.
If unit overheats, output stops, a
Help message is displayed (see
Section 5-3), and cooling fan runs.
Wait fifteen minutes for unit to cool.
Reduce amperage or duty cycle be-
fore welding.
Y Exceeding duty cycle can
damage unit and void war-
ranty.
A
Ref. SA-178 651
OM-202 137 Page 13
KW