Connecting up the Converter
4.2
Connection Example Pressure Sensor
600 bar, 0...20 mA
0...20 mA
0 V / GND
U
/ V+
B
54
Current
-20...+20 mA
-200...+200mA
GND
Sensor Supply +24V
Configuration
(using HPMComm PC software)
Sensor input: 0...600 bar
Sensor output: 0...3 V
Handmeter
Analog
HPM
SCM-
155-0-00
4000
V1.0/05/17