1. General
1.1 Use
2
LINE 10020042.xx exterior sensors are designed to detect the opening (and closing) of an
0
opening such as a door, window, etc... Each sensor comprises 2 parts, a leakproof sensor (large
casing) and a magnet (small casing). As the sensor is supplied by a solar cell, it is maintenance-
free. As soon as the magnet moves relative to the sensor, a radio signal is immediately sent.
Moreover, the signal is retransmitted every 15 minutes.
Before any use, the sensor must be associated with a receiver. (Maximum 2 sensors). Each
sensor can control an unlimited number of receivers.
Note: Read the operating manual carefully before initial use.
1.2 Guarantee terms
This operating manual is an integral part of the device and our guarantee terms. It must always
be delivered to the user. We reserve the right to modify the technical design of these devices
0
without warning. TRI
SYS products are manufactured and their quality checked by making
2
use of the latest technologies and taking into account the applicable national and international
directives. If nevertheless a fault arises, TRI
without prejudicing the rights of the end customer that arise from the sales contract with his
reseller:
If the event of exercising of a legitimate and regular right, TRI
rectify the device fault or supply a fault-free device. Any claim beyond this and all claims for
consequential damages are excluded.
A legitimate fault exists if the device cannot be used at the time of delivery to the end customer
because of a design or manufacturing defect or if its practical use is severely limited. The
guarantee is void in cases of natural wear and tear, incorrect use, incorrect connection, where
the device has been repaired or external influence. The guarantee period is 24 months (from the
date of invoicing). French law applies to the regulation of guarantee rights.
1.3 Recycling of the device
According to the European directives 2012/19/UE relative to electrical and
electronic equipment waste, 2006/66/CE relative to batteries and accumulator as
well as batteries and accumulator waste and their enforcement according to the
national legislations, this logo means that you should not throw the out-of-service
devices with household waste. Dangerous substances which they may contain can
damage the health and the environment. Make take back these devices by your
distributor or use the means of differentiated waste collection provided by your municipality.
2. Safety
Observe the following points:
• The laws, standards and directives in force.
• Best practice at the time of installation
• The device operating manual.
• An operating manual can only give general instructions. They must be interpreted in the
context of a specific installation.
The device is intended solely for use conforming to its purpose. Any repairs or modifications by
the user are forbidden! Do not use with other devices the operation of which could endanger
people, animals or property.
3. Technical characteristics
General characteristics
Transmission frequency
Transmission power
EnOcean Equipment Profile
Ambient temperature
Storage temperature
Illumination
Degree of protection
Install altitude
Range in buildings
Masonry
20m, through 3 walls at most
Reinforced concrete
10m, through 1 wall/ceiling at most
Plasterboard / wood
30m, through 5 walls at most
Note: The signal strength between the transmitter and the receiver decreases as the distance
increases. Where there is a line-of-sight connection, the range is approximately 30 m in corridors
and 100 m in large workshops or halls. The range can be increased with an
TOC1208NUbb_0221
EN
0
SYS undertakes to remedy the default as follows,
2
0
SYS, may at its sole discretion,
2
From 868.0 MHz to 868.6 MHz
10 mW max.
D5-00-01
From -10°C to +60°C
From -20°C to +60°C
>100 lux on average per day
IP 54, on its base
2000m max.
0
LINE repeater.
2
4. Installation and initial use
The sensor is supplied on a base which as well as installation allows a learn process to be
performed close to the matched receiver by separating (using a small screwdriver to depress the
clips) the sensor from the base; the base remaining in position.
Base clip
< 5 mm
Screw cap
4.1 Installation instructions:
Never mount the sensor in a metallic casing or close to a largely metallic object.
Installation on the ground or close to the ground is not recommended
· For effective detection, the pointers must be accurately aligned.
· Secure the magnet by gluing or screwing: 3mm screw, max head diameter 6mm.
· Once positioned, attach the 2 screw caps.
· Secure the sensor by gluing or screwing at a maximum distance of 5 mm from the magnet.
· Place the sensor on its base until it engages.
4.2 Initial use:
The devices are supplied in an operational state but will probably require recharging, following
storage of the radio sensors in the dark.
· Prior to first use, charge the sensor's power reserve using light with an illuminance of at
least 200 lux for 5 minutes or more.
· Ensure that averaged across the day, the mean illuminance is 100 lux/d.
· The sensor's operating power reserve (when fully charged) in conditions of total darkness
is 7 days.
Note: To clean, simply wipe using a damp cloth!
5. Controls and functions
ion and initial use
10020042.xx detectors transmit the detection of opening using the frame described in the
EnOcean Equipment Profiles EEP document §D5-00-01 (consultable under
alliance.org).
5.1 Detection of opening:
Each time the magnet leaves or returns to its installation position, a radio signal will be
transmitted.
5.2 Programming and LRN button:
Switch the receiver to learn mode and by pressing
the LRN button placed behind the sensor, initiate
the sending of an association frame.
When the sensor is located on its base, it must be
first unclipped from the base to access the LRN
button and to place the sensor closed to the
matched receiver during the identification or
association phase (the receiver having reduced sensitivity during this phase).
6. Troubleshooting
ion and initial use
6.1 New or existing installation
• If the receiver functions at a shorter distance relative to the sensor, it is subject to interference
or used outside the transmission range.
• Search the system environment for changes that could cause the interference (for example
movement of metallic cabinets, furniture or partitions).
• Use the sensor or receiver in a more suitable location.
• Clear the receiver and perform a new learn process.
6.2 Limitation of the range of the radio signals
• Transmitter/receiver used close to metallic objects or close to materials containing metallic
elements. Observe a distance of at least 10 cm.
• Humidity in the materials.
• Devices emitting high frequency signals such as audio and video systems, computers,
electronic ballasts or fluorescent tubes. Observe a distance of at least 0.5 m.
6.3 Contacts
E-mail: ............................
contact@trio2sys.fr
7. Declaration of conformity
This product can be sold and operated in the countries of the European Union. Hereby,
0
TRI
SYS
declares that radios equipment 10020042.xx are in compliance with directive
2
2014/53/EU, known as the RED Directive.
The full text of the EU declaration of conformity is available at the following internet address:
www.trio2sys.fr
78 mm
25 mm
13 mm
41 mm
www.enocean-
LRN button
D.Girard
2/2