Télécharger Imprimer la page

Palram Olympia Mode D'emploi page 60

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 11
PALRAM Applications (1995) Ltd.
Teradion Industrial Park, M.P Misgav 2017400, P.O.B 53, Israel
Tel +972.4.848.6900 | Fax +972.4.848.6901
applications@palram.com | www.palramapplications.com
According to Construction Products Council Directive UE N°305/2011 and EN 14963:2006
1. Identification code: Olympia™, refer to CE label no 054
2. Type: A light transmitting wall-supported Twin-wall PC roofing structure with upstand made of aluminum
and galvanized steel elements
3. Intended use: open multi-purpose covering where the ground slope is less then 5%
4. Manufacturer: Palram Applications (1995) Ltd. Teradion Industrial Park, M.P Misgav 2017400, P.O.B. 53, Israel
5. Importer and EU representative : PALRAM Applications UK, Unit 40 J3 Industrial Estate Carr Hill,
Doncaster DN4 8DE
6. Assessment and verification of constancy of performance: System 3
7. Declared performance:
Resistance to upward load: UL 1000
Resistance to downward loads: DL 1500
Reaction to fire: B, s1, d0
For mounting and fixing provisions see EN 16153:2013
Resistance to fire: NPD
External fire performance: F
Water tightness:
For the rooflight with upstand: Pass
For the sheet material: Pass
Impact resistance:
For the small hard body: Pass
For the large soft body: NPD
Thermal transmittance:
For the rooflight: NPD (not relevant to an open multi purpose cover)
For the sheet material: 2.10 W/(m²•K)
Direct airborne sound insulation: NPD (not relevant to an open multi purpose cover)
Radiation transmittance:
- Light transmittance: Tv - 61.0 %
- Solar direct transmittance: Te - 49.1 %
- Solar factor: g value - 0.52
Air permeability:
For the rooflight: NPD (not relevant to an open multi purpose cover)
For the sheet material: Pass
Durability (of the sheet material): ΔA, Cu 1, Ku 1
8. The performance of the product identified in points 1 and 2 is in conformity with the declared
performance in point 7.
This declaration of performance is issued, in accordance with Annex ZA.2.2 – EN 14963:2006,
under the sole responsibility of Palram Applications (1995) Ltd.
ITT reports and Factory Production Control records are available upon request at
www.palramapplications.com
Signed for and behalf of Palram Applications (1995) Ltd. by:
Teradion Industrial Park, Misgav,
Declaration of Performance
Issue Date 23/02/2017
ROOF
23/02/2017