Installation distances
C856W Style
Combustible roof
INSTALLATION AGAINST COMBUSTIBLE WALLS
Permitted area for
combustible parts
of the building
Combustible wall
* There must be a minimum distance of 50 mm/285 mm. If mounting on Contura's corner bracket, the distance must be 56 mm/291 mm.
** To prevent discolouration of painted non-flammable walls we recommend that the same side distance as to combustible walls is used.
465
400
300
Fire-retardant wall of
100
brick or concrete
500
730
The minimum distance in front of
the stove opening to combustible
parts of the building or interior
decoration must be at least 1,1 m.
E = minimum height to sloped ceiling
from the centre of the chimney
380
Ø150
59
106
Air inlet Ø67
INSTALLATION AGAINST FIREWALLS
750
Fire-retardant wall of
brick or concrete
50*
285*
800
Fire-retardant wall of
brick or concrete
200**
430**