THE POWER CABLE MUST BE REPLACED BY QUALIFIED PERSONNEL ONLY. USE AN
ORIGINAL POWER CABLE ONLY WITH A 3-PIN APPROVED PLUG.
THE FRONT OUTLET IS VERY HOT DURING OPERATION. DO NOT TOUCH! BURN
DANGER.
2. Product Description
Diesel or Kerosene direct-fired mobile/portable space heater with open combustion chamber and indirect fired
mobile/portable space heater with close combustion chamber
3. Technical Specifications
Model
Heat Input* [kW] [Hs]
Air Flow Rating [m³/h]
Fuel Type
Fuel consumption [l/h]
Fuel Nozzle size
Voltage [V]
Electrical Power rating [W]
Pump Pressure Setting [bar]
Current Rating [A]
Fuse Rating
Air collar setting [notch]
Dimensions
Net Weight (kg)
Length (mm)
Width (mm)
Height (mm)
Tank Capacity (l)
Operating range (h)
Standard Accessories
Fuel gauge
Handle
Ambient thermostat
Malfunction detection signal
*Based on dedicated setting for standard condition (atmospheric pressure 1020 hPa and Temperature 20 °C).
DH2-I-85
DH2-I-55
52.5
2500
Diesel - Kerosene
Diesel - Kerosene
4.8
1.50 gph-80°
1.00 gph-60°
230V 50Hz
230V 50Hz
720
12.0
3.2
T6.00 A
T6.00 A
3
58.0
1385
600
785
55
~11
yes
1
built-in
built-in
built-in
built-in
Fig.1
DH1-70
82,9
67.9
3900
2200
Diesel - Kerosene
7.7
6.3
1.35 gph-60°
230V 50Hz
900
580
12.0
11.0
3.9
2.6
T6.00 A
4
-
78
43.0
1650
1200
690
600
1040
755
110
55
~14
~9
yes
yes
1
1
built-in
built-in
4.
Assembling Instructions
Extract the heater from its carton. If the unit is anyhow
damaged, do not use it and contact your dealer.
The following accessories are supplied in the shipping
carton.
Pos.
Description
A
Handle
B
Screw M5
C
Heater body
D
Wheel shaft
E
Wheel
F
Spring washer
G
Spacer
H
Nut M5
I
Feet pipe
DH1-100
97.2
2700
Diesel - Kerosene
9.0
1.75 gph-60°
230V 50Hz
700
12.5
3,1
T6.00 A
8
58
1470
690
830
110
~12
yes
1
built-in
built-in
Qty
1
6
1
1
2
2
2
6
1