Control elements
1 Air flow regulator
2 Flame regulator
3 Push button for ignition
4 Flame nozzle
5 Fixing switch for
continuous operation
6 Handle
7 Refill valve, below (not
visible)
8 Base
Operation
a) Filling butane gas
Keep the hot-gas burner away from fire and other heat sources while filling it. Only
fill the hot-gas burner after it has cooled down completely!
Make sure that the room is properly vented.
Do not ignite the hot-gas burner immediately after filling. Butane gas is heavier than
air and will remain on the ground for some time.
Never press the ignite button while filling the burner.
• Butane gas (lighter gas) is required to refill the hot-gas
burner. Shake the gas can a few times before inserting
the refill needle.
• Hold the hot-gas burner upside down by the handle (6).
Insert the needle on the butane gas can into the refill
valve's opening (7) to start filling the cylinder.
• The cylinder holds between 10 - 12 ml of butane gas. Stop
refilling as soon as the gas overflows.
• Wipe away any spillage gas with a clean cloth. Wait
approximately 2-3 minutes before igniting the flame.
b) Application
• Before igniting the flame, the air flow regulator (1) must be between the "Jet" marking and
middle position. The flame will not ignite at the "Flame" position.
• Press down the push button (3) to ignite the flame. When you release the button, it jumps
back automatically to its starting position and the flame goes out. It can take up to 2-3 seconds
for the flame to go out as a small amount of residual gas may be left in the flame nozzle (4).
• Press and hold the push button and slide the a fixing switch (5) back to the lock position
to switch the hot-gas burner to continuous operation. Slide the fixing switch back to end
continuous operation. The push button releases automatically when released. The flame
goes out after a short time.
• Set the flame size using the flame regulator (2). Turn the control knob toward "OPEN" to
increase the flame size and away from the arrow to reduce the flame size. When the flame
falls below approx. 10 mm in length, it goes out.
Yellow-red (Flame)
• You can change the flame colour using the air flow regulator (1). The flame colour may be set
between blue (arrow direction "Jet") to a natural red-yellow (arrow direction "Flame"). Turn the
air flow regulator in the desired direction.
• Please note that the flame will not go out immediately after releasing the push button, but
only after about 2-3 seconds. Only then place the hot gas burner on its base (8) and allow it
to cool down sufficiently.
1
2
3
4
5
6
7
8
Blue (Jet)
Troubleshooting
Problem
Possible cause
Ambient temperature too cold.
Flame too small.
Gas cylinder too cold.
Not enough gas.
Flame nozzle (4) soiled.
No flame, device
Flame regulator (2) is closed.
does not ignite.
Push button for ignition (3)
cannot be pushed.
Air flow regulator is at "Flame"
Care and cleaning
• Never use aggressive detergents, rubbing alcohol or other chemical solutions, as these could
damage the casing or cause the product to malfunction.
• Use a dry, lint-free cloth to clean the product.
• Remove any residual gas before storing the hot-gas burner.
Disposal
At the end of its service life, dispose of the product according to the relevant statutory
regulations.
You thus fulfil your statutory obligations and contribute to the protection of the environment.
Technical data
Flame temperature ....................... max. approx. 1300 °C
Gas cylinder capacity ................... 12 ml
Operating time ..............................with one gas filling max. approx. 30 min.
Operating conditions ..................... +10 to +40 ºC, 10 – 90 % relative humidity
Storage conditions ........................ 0 to +50 ºC, 20 – 70 % relative humidity
Dimensions (W x H x D) ............... 138 x 190 x 62 mm
Weight .......................................... 320 g
This is a publication by Conrad Electronic SE, Klaus-Conrad-Str. 1, D-92240 Hirschau (www.conrad.com).
All rights including translation reserved. Reproduction by any method (e.g. photocopying, microfilming, or the capture in
electronic data processing systems) requires prior written approval from the editor. Reprinting, also in part, is prohibited.
This publication represents the technical status at the time of printing.
Copyright 2017 by Conrad Electronic SE.
Solution
Go to a warmer area.
Try warming the grip with the gas
cylinder by hand or wait until the
gas cylinder has warmed up.
Refill gas.
Remove dirt from the flame
nozzle.
Turn the flame regulator toward
"OPEN" to increase the flame
size.
Slide the fixing switch forward to
release the push button.
Turn the air flow regulator to "Jet"
or the middle position.