Problems & Faults - Cross Tools ICEBOX 40 Traduction Du Mode D'emploi D'origine

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 18
Humidity in the air can form frost inside the cooling unit, which also reduces the cooling performance.
Defrost the cooling unit in good time and regularly.
Proceed as follows to defrost the cooling unit:
Switch off the cooling box and disconnect the mains plug.
Open the lid and remove all items from the cooling unit.
If necessary, store the goods in another cooling unit so that they stay cold and do not thaw out.
Leave the lid open to defrost the ice more quickly.
Never use hard, sharp or pointed tools to remove the layers of ice or to loosen frozen items. Disre-
gard can cause damage to the unit.
Remove the drain plug in the base to allow the water condensate to drain out. Dry the interior with a
soft cloth.
Close the drain plug.
The cooler is now ready for use again.
7. Problems & faults
The following operating noises may occur during normal operation and do not indicate a malfunction:
When starting or stopping the compressor, the refrigerant flow may cause a strong humming, gur-
gling or pulsating noise.
Metallic vibration sounds may be heard from the compressor when the device starts working and the
cooler starts cooling.
If the device does not operate or start:
Check the mains connection (if using vehicle power, check the ignition).
Check that the plug and socket have a good connection.
Check if the fuse is blown (see paragraph Replace fuse).
Check whether the device is or has been switched on.
Check if any of the error messages described below are shown on the display:
7.1 Fault table and error codes
In the event of a fault, the internal device management system can display various error codes in order to identify
possible causes:
Fault
1. Food or drinks inside the
cooler are frozen
2. Food or drinks inside the
cooler do not get cold
3. Sound of running water
inside the box
4. F1 code
displayed
5. F2 code
displayed
6. F3 code
displayed
7. F5 code
displayed
8. F6 code
displayed
9. F7/F8 code
displayed
14
Possible cause
1. The temperature set is
too low
1. The temperature set is
too high
1. This is a normal noise
due to the refrigerant
flow.
1. Low battery power
protection activated
1. Fan overload protection
activated
1. The compressor
safeguard is activated
1. The compressor control
module safeguard is
activated.
1. Hardware controller error
(controller could not
recognise the normal
parameters).
1. Temperature sensor fault 1.Please restart the device. If F7/F8 is displayed.
Remedy
1.Adjust the temperature in the panel
1.Adjust the temperature in the panel
1.No remedy necessary or possible as this noise is
normal
1.Change the protection from H3 (H) to H2 (M) or H1
(L)
1.Please switch the device off, store it in a ventilated
place and restart it after 30 minutes. If F2 is still dis-
played, please contact customer service.
1.Please switch the device off, store it in a ventilated
place and restart it after 30 minutes. If F3 is still dis-
played, please contact customer service.
1.Please switch the device off, store it in a ventilated
place and restart it after 30 minutes. If F5 is still dis-
played, please contact customer service.
1.Please switch the device off, store it in a ventilated
place and restart it after 30 minutes. If F6 is still dis-
played, please contact customer service.
6