Télécharger Imprimer la page

CDVI TPV Mode D'emploi page 2

Temporisation pour ventouses

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION MANUAL
TPV
Relay delay board
1] GENERAL INFORMATION
When the opening access is controlled by a push button (N.C.), the TPV
delays the relocking of the electromagnetic lock(s), retrofit housings and handles.
Up to 2 electromagnetic locks, 300, 400 or 500 kg per TPV.
Dimensions (L x W x D): 81 x 26.5 x 11 mm.
Time-lag: adjustment from 1.5 to 20 seconds.
Input voltage: 12/24 V DC.
2] NOTES AND RECOMMENDATIONS
Installation recommendations
One TPV for two electromagnetic locks, 300, 400
or 500 kg maximum.
Recommended cable
2 pair 6/10th cable for the electromagnetic lock.
1 pair 6/10th cable for the supply voltage.
3] WIRING DIAGRAM
CONNECTION TO ELECTROMAGNETIC LOCK(S) WITH A CONNECTING BLOCK
TIME DELAY
ADJUSTMENT :
Push button
(NC contact)
CONNECTION TO ELECTROMAGNETIC LOCK(S) WITHOUT A CONNECTING BLOCK
TIME DELAY
ADJUSTMENT :
Push button
(NC contact)
2
cdvigroup.com
Recommended power supplies
There are two power supplies suitable
for this product :
- ARD212, ADC335 or BS60,
- BS602 or AL500.
1.5s
20s
12VDC
1.5s
20s
12VDC
BLACK
Power supplies : 12VDC or 24VDC
Which power supply goes to your electromagnetic
lock depends on the position of the jumpers
12VDC or 24VDC.
24VDC
RED
ELECTROMAGNETIC
GREEN
LOCK (S)
WHITE
BLACK
Power supplies : 12VDC or 24VDC
Which power supply goes to your electromagnetic
lock depends on the position of the jumpers
12VDC or 24VDC.
24VDC
RED
EN
WEEE & RoHS
CE Certification
ELECTROMAGNETIC
LOCK (S)

Publicité