BPT12-13H1
BATHROOM EXHAUST FANS
INSTALLATION INSTRUCTIONS
CONNECTING WIRING FROM UNIT TO HOUSE
4.
(FIGURE 4)
WARNING: Make sure that the main power is off.
WARNING: Failure to wire product correctly could result in
electrical shock, fire hazards, or damage to the product.
Consult a licensed electrician if you are unsure of your ability
to correctly install wiring.
CAUTION: If your house wires do not match these colors,
determine what each house wire represents before connecting.
You may need to consult a licensed electrician to determine this
safely.
a) Connect house wires to ventilation fan wires.
b) Match colors as shown (black to black, white to white, and green
to green) using quick connects or wire nuts (not provided).
c) Replace the junction box cover. Do not pinch the lead wires.
INSTALLING FAN GRILL (FIGURE 5)
5.
a) Insert the mounting springs into the grill.
b) Squeeze mounting springs together, and insert into main body.
CLEANING
CAUTION: Do not use solvents, thinner or harsh chemicals for cleaning the fan.
CAUTION: Do not allow water to enter the motor.
CAUTION: Do not immerse resin parts in water over 140° F (60° C).
a) Before servicing or cleaning the unit, disconnect the power supply at the panel and lock to prevent the power from being turned
on. If the panel cannot be locked, clearly mark the panel with a warning tag to prevent the power from being turned on.
b) Remove the grill by squeezing the springs and pulling the grill down.
c) Wash and clean the grill in a sink and dry with a cloth.
d) Remove dust and dirt from the fan housing with a vacuum cleaner.
e) Dampen a cloth with dish detergent, wipe the fan housing and dry with a cloth.
f) Replace the grill.
g) To reduce the risk of fire, always vent fans to the exterior and in compliance with local codes. Do not vent exhaust air into spaces
within walls, ceilings, attics, crawl spaces, or garages.
h) Unplug or disconnect the appliance from the power supply before servicing.
WARRANTY
We guarantee this fan to be free of defects, in material and workmanshipp, for a period (1) one year, from date of purchase. During this
period, we will, at our option repair or replace and defective product or part, which is returned freight prepaid to the nearest distributor.
This warranty does not include any labour or transportation costs incidental to the removal or re-installation of the said products at the
uner's premises. This warranty is void in the case of alteration, accident, abuse or operation not in accordance with the operation/
assembly instruction.
NOTE: Please DO  NOT remove your cULus label as this will void the warranty. The cULus lable must be affixed to process warranty
claims.
As a result of varying climatic conditions in our area, this warranty does not cover any changes in finishes, including rusting, pitting,
corroding, tarnishing or peeling.
Installation or Product problems? Do not return to store of purchase.
Contact Canarm Service at 1-800-265-1833 (CANADA), 1-800-267-4427 (U.S.A.),1-800-567-2513 (EN FRANCAIS)
Canarm Ltd. - Corporate Head Office
2157 Parkedale Ave. PO Box 367 Brockville, ON Canada K6V 5V6
BPT12-13H1-M-05_27_21
Monday to Friday 8:00 - 5:00pm e.s.t. or visit www.canarmna.com
CONTINUED...
AUTOMATIC TERMINAL
CAPACITOR
QUICK
CONNECT
PRODUCT WIRES
CANARMNA
CANARMNA
www.canarmna.com
JUNCTION BOX
MOTOR
HOUSE WIRES
Tel: (613) 342-5424; Fax: (613) 342-843
CANARMNA
CANARMNA
FIGURE 4
(black) to switch
(white) to neutral
(green) to ground