CAUTION: Be sure that incoming power is turned off.
1.
With your desired mounting height from cooking surgace, measure from bottom
of hood 6" up and draw a line.
2.
U-Shape Bracket is secured to the hood brackets with nuts & screws during
shipping. Remove the U-Shape bracket from hood brackets.
3.
Take "U" shape installation bracket and line the bottom of the bracket up with the
line (center bracket left to right) install bracket using #10 x 2-1/2" wood screws, if
you have wood to screw in to. If not use the 3/16" x 3" toggle bolts.
4.
Lift up hood and connect hood brackets to installation bracket using (8) 10-32
Hex Keps nuts and (8) 10-32 x 3/4 screws. Make sure hood is level before you
tighten all screws.
5.
Use (2) 3/16" x 3" toggle bolts or #10 x 2-1/2" wood screws and (2) 1-1/4" OD
Fender washers to secure to back of wall.
6.
Bring wires down and feed through 7/8" hole on top of the hood, at least 8" to 10"
long.
7.
Remove junction box. (Be sure to comply with all local electrical and safety
codes) Units are to be hard wired. It is not recommended to
add a power-cord. Adding a power cord can loosen existing
wires inside junction box causing electrical failure.
8.
Remove Black Tape that holds the Damper Blades in closed
position. Attach special length of vent pipe to the vent opening on
top of hood. *It is NOT recommended to use 2 dampers
during installation. You have the option to put a external
damper or use the existing damper already on the unit.
Duct Sizes Indicated in Model # (Ex: WH2048PSSB-K)
** - 8 = 8" DUCT PIPE
** - K=10" DUCT PIPE
If not indicated by an 8 or a K, duct pipe is 7"
Round.
Wall Mount Installation Detail:
Refer to
#2
(Top View)
MODELS:
WHN2000PS1-TWSB
Refer to #3 (U-Shape Bracket)
Refer to #5
Black Tape on Damper