BEFORE THE FIRST OPERATION
For the perfect taste, operate the jug kettle with fresh water in order to clean any residue left
from the manufacturing process. When the appliance has cooled down, repeat the process 3
times with fresh water, before rinsing.
OPERATION
Open the lid by turning it anti-clockwise and take it off. Fill in cold drinking water or other
to be warmed up potations. Please always check that the liquid inside the unit is covering
the bottom of the tank, otherwise the unit (heating element) could be damaged. As
minimum mark for filling in liquid take the height of the outlet. Never fill in less than this
mark. Do not exceed the maximum mark.
You can read the quantity of potation on the water gauge (3).
Close the lid by turning it clockwise until it is locked in place.
Insert the power plug into the power socket.
Maximum capacity of the tank: 6.8 litres
BOIL FUNCTION
Attention: Please only boil water. Other liquids (potations) please only warm up!
Pour the desired amount of water/potation into the water tank.
Switch on the unit by putting the on-off switch (9) in position "I". The yellow standby light
(10) will be illuminated. Turn the temperature switch (1) towards position 100°C. The red
indicator lamp (8) lights to indicate that the unit is heating up.
The content will be warmed up and the unit deactivates automatically as soon as the
water boils. You can discontinue the boil function at any time by turning the temperature
switch towards position „°C" and pressing the power button (into position "0").
Warm up function (keep warm function)
Pour the desired amount of water/potation into the water tank.
Switch on the unit by putting the on-off switch (9) in position "I". The yellow standby light
(10) will be illuminated. Turn the temperature switch (1) towards the desired temperature
position. The red indicator lamp (8) lights to indicate that the unit is heating up.
After warming up the temperature will be kept relatively constant. The temperature will be
controlled by an integrated thermostat. During the keeping warm process the active light
is on, when the heating element is on for a short time in order to reheat the liquid. After the
thermostat has switched off, only the yellow light is on until the thermostat will switch on
the unit again. So the active light is only on when the thermostat activates the heating
element.
You can discontinue the warming up function at any time by turning the temperature
switch towards position „°C" and pressing the power button (into position "0").
Spigot
There are 2 positions for the spigot. In normal position the spigot is closed (lever in vertical
position). If you push the lever down to a fixed position (horizontal position), the outlet is
open permanently.
OVERHEATING PROTECTION
Copies of the I/B. Please reproduce them without any
changes except under special instruction from Team
International BELGIUM. The pages must be reproduced
and folded in order to obtain a booklet A5 (+/- 148.5 mm
width x 210 mm height). When folding, make sure you
keep the good numbering when you turn the pages of
the I/B. Don't change the page numbering. Keep the
language integrity.
Back cover page (last page)
Assembly page 11/31

Publicité

loading

Ce manuel est également adapté pour:

180528