Austro Flamm G3 Manuel D'instructions page 6

Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

G3
1. TECHNICAL DATA
As a stove of construction type 1, it is possible to
connect it to the flue pipe of an existing other stove
or another hearth for solid fuels, as long as the
chimney complies with DIN 4705, Part 3.
TECHNICAL DATA
Height
Width
Depth
Weight
Weight with ceramic shell
Flue pipe outlet diameter
Nominal thermal output EN 13240
Maximum thermal capacity
Smallest heating capacity
2. IMPORTANT INFORMATION
The installation and operation information given here
. National and European
is of general nature
standards, local and building regulations as well as
fire prevention laws must be observed during the
operation of the stove.
General safety instructions for
the operation of your stove
Thoroughly read the entire manual before
starting up your stove and observe the caution
notices.
Your heating unit may not be moved without
approved means of transport with sufficient load-
bearing capacity.
Your heating unit is not suitable to be used as a
stand or as a ladder.
The burning of fuel releases thermal energy that
leads to a substantial heating up of the surface of the
heating unit, the doors and operating handles
mounted on the door, door glass, flue pipe and in
some cases the front wall of the heating unit. Do not
touch any of these surfaces without respective
protective clothing or without the help of accessories
such as heat-resistant gloves or a cold hand.
Make your children aware of this particular
danger and keep them at a distance from the heating
unit whenever it is in operation.
Only burn approved fuels and materials listed in
the chapter "Clean Burning".
The burning or placing of flammable or explosive
materials, such as empty spray cans and such like
into the firebox as well as the storage of such
materials in the immediate vicinity of your heating unit
is strictly forbidden due the danger of explosion.
Do not wear loose or flammable clothing when
adding fuel to the fire.
4
Room heating capacity (depending on
building insulation)
Exhaust values for multiple use of the chimney in
accordance with DIN 4705, Part 3 and for the
calculation of the chimney measurements in
793 mm
accordance with DIN 4705, Part 2
453 mm
Fluegas mass flow
510 mm
Fluegas temperature
120 kg
Minimum feed pressure
170 kg
Nominal thermal output
130 mm
6 kW
8 kW
3 kW
Placing non-heat-resistant objects on the
heating unit or in the vicinity of the heating unit is
forbidden.
Do not lay laundry onto the stove for drying.
Laundry hung up to dry must be kept at a safe
distance from the stove because of the danger of fire.
The woodstove G3 is not suitable for long term
heating.
During the operation of your heating unit it is
forbidden to use flammable or explosive materials in
the same or an adjacent room to the one in which
your heating unit is located
Setting Up Your Stove
Required safety distances
distances – see name plate - in Fig. 2)
1. to nonflammable objects:
a > 400 mm
2. to flammable objects and to supporting walls of
reinforced-concrete construction with convection
shell:
I - a > 800 mm b > 200 mm c > 300 mm
II - a > 800 mm b > 300 mm c > 300 mm
III - a > 800 mm b > 500 mm c > 300 mm
I = with stainless steel cladding
II = with convection cladding
III = without convection cladding
(a – toward the front in the radiated area)
(b – to the side) (c – to the back)
Make sure that the room in which the stove is set up
has at least one door or window into the outside or is
directly adjacent to such a room. Other fireplaces and
extractor hoods must not be operated in the same
room as the stove.
closed
closed
closed
at 0.8 times
n. ther. outp.
.
b > 200 mm c > 300 mm
english
48–124 m³
7 g/s
380 °C
12 Pa
10 Pa
(Minimum

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Gussofen g3

Table des Matières