The ORITEL TGN 100 waveguide-to-coax transition element is a microwave component specially
designed for the ORITEL BDH R100 educational bench, manufactured using a rectangular waveguide
in accordance with the R100/WR90 standard (covering the frequency range between 8.5 and 9.6 GHz).
This element enables a transmission line in a waveguide to be connected to a female N-type coax and
vice versa. By connecting an ORITEL DEN 100 coaxial detector to its output, you have an assembly
making it possible to convert the modulated microwave signal to weak or zero frequency signals.
See § 7.1
Female «N» connector.
Knurled tightening knob for the EASYFIX quick fastening lug.
Generally speaking, the components below are a part of the standard supplies delivered with the ORITEL
BDH R100 basic educational bench.
To use these components, refer to their respective operating manuals.
3.1
Summary list of the components making up the ORITEL BDH R100
basic educational bench
ORITEL OSG 100 Gunn diode oscillator ............................................................................. P01.2753.07
ORITEL ISO 100 ferrite isolator ........................................................................................... P01.2753.08
ORITEL MOD 100 pin diode modulator ............................................................................... P01.2753.09
ORITEL ATM 100 micrometer-adjustable variable attenuator ............................................. P01.2753.10
ORITEL OND 100 curve wavemeter .................................................................................... P01.2753.11
ORITEL LAF 100 measuring line ......................................................................................... P01.2753.12
ORITEL ADZ 100/3 three-screw impedance adaptor .......................................................... P01.2753.13
ORITEL TGN 100 waveguide-to-coax transition element .................................................... P01.2753.14
ORITEL DEN 100 coaxial detector ...................................................................................... P01.2753.15
ORITEL CHG 100 adapted load .......................................................................................... P01.2753.16
ORITEL CC 100 short circuit plate ...................................................................................... P01.2753.17
ORITEL SUP 100 waveguide support ................................................................................. P01.2753.18
1. PRESENTATION
2. DESCRIPTION
3. USE
7